BACKGROUND Hereditary hemorrhagic telangiectasia(HHT)is an autosomal dominant genetic disorder with an incidence of approximately 1 in 5000 in the general population.It is characterized by vasodilation,which affects s... BACKGROUND Hereditary hemorrhagic telangiectasia(HHT)is an autosomal dominant genetic disorder with an incidence of approximately 1 in 5000 in the general population.It is characterized by vasodilation,which affects specific organs,such as the skin,mucous membranes,brain,lungs,gastrointestinal tract,liver,and others.However,HHT rarely involves the portal venous system to cause serious clinical compli-cations.CASE SUMMARY A 68-year-old woman was admitted to the emergency department due to four consecutive days of abdominal pain and bloody stool and was subsequently diagnosed with HHT.Computed tomography angiography confirmed the presence of an arteriovenous fistula(AVFs).Considering this specific manifestation,whole exome sequencing was performed.After a comprehensive evaluation,a selective superior mesenteric artery embolization was prioritized to avoid intestinal ischemia.The postoperative symptoms of the patient were quickly relieved.Unfortunately,two months post-procedure the patient died from intestinal necrosis and abdominal infection related to remaining AVFs.CONCLUSION For patients with diffuse superior mesenteric AVFs,selective mesenteric arterial embolization may lead to positive short-term outcomes. 展开更多
关键词 Hereditary hemorrhagic telangiectasia Portal system Arteriovenous fistula Arteriovenous malformation Selective artery embolization Case report
下载PDF
Comparative analysis of technical requirements for Heating,Ventilating,and Air Conditioning(HVAC)systems in high-biocontainment facility standards
2
作者 Lei Liang Xinfang Hong +7 位作者 Bing Lu Xuedong Yu Guoqing Cao Xin Feng Quan Zhou Yanqin Wang Donglai Wu Rong Wang 《Biosafety and Health》 CSCD 2023年第1期1-7,共7页
In this study,standards of high-biocontainment facilities(including laboratories and large-scale production facilities)formulated by China and other countries were analyzed and compared,and the technical points and re... In this study,standards of high-biocontainment facilities(including laboratories and large-scale production facilities)formulated by China and other countries were analyzed and compared,and the technical points and requirements for Heating,Ventilating,and Air Conditioning(HVAC)systems in different series of standards were discussed.The main focus was on expounding the design and verification of the containment area’s indoor parameters,ventilation system,filter design,integrity test,fan standby,airflow pattern,and system reliability.This study expects suggestions and opinions on the construction and development of biosafety facilities in China and the possible future revision of relevant national standards. 展开更多
关键词 High-biocontainment facilities HVAC systems STANDARDS Technical requirements