Online Fault Detection Configuration on Equipment Side of a Variable-Air-Volume Air Handling Unit
1
作者 杨学宾 李鑫海 +2 位作者 杨思钰 王吉 罗雯军 《Journal of Donghua University(English Edition)》 CAS 2023年第2期225-231,共7页
With the development of the technology of the Internet of Things,more and more operational data can be collected from air conditioning systems.Unfortunately,the most of existing air conditioning controllers mainly pro... With the development of the technology of the Internet of Things,more and more operational data can be collected from air conditioning systems.Unfortunately,the most of existing air conditioning controllers mainly provide controlling functions more than storing,processing or computing the measured data.This study develops an online fault detection configuration on the equipment side of air conditioning systems to realize these functions.Modbus communication is served to collect real-time operational data.The calculating programs are embedded to identify whether the measured signals exceed their limits or not,and to detect if sensor reading is frozen and other faults in relation to the operational performance are generated or not.The online fault detection configuration is tested on an actual variable-air-volume(VAV)air handling unit(AHU).The results show that the time ratio of fault detection exceeds 95.00%,which means that the configuration exhibits an acceptable fault detection effect. 展开更多
关键词 fault detection software configuration online monitoring equipment side variable-air-volume(VAV) air handling unit(AHU)
下载PDF
Calibration of a compact absolute atomic gravimeter 被引量:6
2
作者 谢宏泰 陈斌 +3 位作者 龙金宝 薛春 陈泺侃 陈帅 《Chinese Physics B》 SCIE EI CAS CSCD 2020年第9期84-91,共8页
Compact atomic gravimeters are the potential next generation precision instruments for gravity survey from fundamental research to broad field applications.We report the calibration results of our home build compact a... Compact atomic gravimeters are the potential next generation precision instruments for gravity survey from fundamental research to broad field applications.We report the calibration results of our home build compact absolute atomic gravimeter USTC-AG02 at Changping Campus,the National Institute of Metrology(NIM),China in January 2019.The sensitivity of the atomic gravimeter reaches 35.5μGal/√Hz(1μGal=1×10-8 m/s2)and its long-term stability reaches 0.8μGal for averaging over 4000 seconds.Considering the statistical uncertainty,the dominant instrumental systematic errors and environmental effects are evaluated and corrected within a total uncertainty(2σ)of 15.3μGal.After compared with the reference g value given by the corner cube gravimeter NIM-3A,the atomic gravimeter USTC-AG02 reaches the degree of equivalence of 3.7μGal. 展开更多
关键词 atom interferometry absolute gravimeter systematic errors
下载PDF
Effect of Two Kinds of Similarity Factors on Principal Component Analysis Fault Detection in Air Conditioning Systems 被引量:2
3
作者 杨学宾 何如如 +1 位作者 王吉 罗雯军 《Journal of Donghua University(English Edition)》 CAS 2021年第3期245-251,共7页
Screening similar historical fault-free candidate data would greatly affect the effectiveness of fault detection results based on principal component analysis(PCA).In order to find out the candidate data,this study co... Screening similar historical fault-free candidate data would greatly affect the effectiveness of fault detection results based on principal component analysis(PCA).In order to find out the candidate data,this study compares unweighted and weighted similarity factors(SFs),which measure the similarity of the principal component subspace corresponding to the first k main components of two datasets.The fault detection employs the principal component subspace corresponding to the current measured data and the historical fault-free data.From the historical fault-free database,the load parameters are employed to locate the candidate data similar to the current operating data.Fault detection method for air conditioning systems is based on principal component.The results show that the weighted principal component SF can improve the effects of the fault-free detection and the fault detection.Compared with the unweighted SF,the average fault-free detection rate of the weighted SF is 17.33%higher than that of the unweighted,and the average fault detection rate is 7.51%higher than unweighted. 展开更多
关键词 similarity factor(SF) fault detection principal component analysis(PCA) historical candidate data air conditioning system
下载PDF
Experimental Study and System Identification of Hydrodynamic Force Acting on Heave Damping Plate 被引量:1
4
作者 纪亨腾 范菊 黄祥鹿 《China Ocean Engineering》 SCIE EI 2008年第1期141-149,共9页
Although Morison equation is often applied for simulating hydrodynamic force of marine structure, it may give poor results when non-linear behavior is severe or random wave is encountered. This leads to some modificat... Although Morison equation is often applied for simulating hydrodynamic force of marine structure, it may give poor results when non-linear behavior is severe or random wave is encountered. This leads to some modifications of Morison equation or other methods for predicting hydrodynamic force. One of them is the system identification technique. In this paper, NARMAX model theory is firstly used to identify the hydrodynamic system of heave damping plates, which are commonly installed on spar platform. Both linear and non-linear models are obtained. The comparisons between the predieted results and measured data indicate that NARMAX model can predict hydrodynamic force of a heave damping plate very well. The measured data for identification originate from forced oscillation tests, which are random records with given spectrum. The forced oscillation forms in experiment also contain simple harmonic, multi-frequency ones. 展开更多
关键词 heave damping plate Morison equation system identification NARMAX model
下载PDF
Influence of Three Sizes of Sliding Windows on Principle Component Analysis Fault Detection of Air Conditioning Systems 被引量:1
5
作者 杨学宾 马艳云 +2 位作者 何如如 王吉 罗雯军 《Journal of Donghua University(English Edition)》 CAS 2022年第1期72-78,共7页
Principal component analysis(PCA)has been already employed for fault detection of air conditioning systems.The sliding window,which is composed of some parameters satisfying with thermal load balance,can select the ta... Principal component analysis(PCA)has been already employed for fault detection of air conditioning systems.The sliding window,which is composed of some parameters satisfying with thermal load balance,can select the target historical fault-free reference data as the template which is similar to the current snapshot data.The size of sliding window is usually given according to empirical values,while the influence of different sizes of sliding windows on fault detection of an air conditioning system is not further studied.The air conditioning system is a dynamic response process,and the operating parameters change with the change of the load,while the response of the controller is delayed.In a variable air volume(VAV)air conditioning system controlled by the total air volume method,in order to ensure sufficient response time,30 data points are selected first,and then their multiples are selected.Three different sizes of sliding windows with 30,60 and 90 data points are applied to compare the fault detection effect in this paper.The results show that if the size of the sliding window is 60 data points,the average fault-free detection ratio is 80.17%in fault-free testing days,and the average fault detection ratio is 88.47%in faulty testing days. 展开更多
关键词 sliding window principal component analysis(PCA) fault detection sensitivity analysis air conditioning system
下载PDF
FLOW REGIME TRANSITIONS IN GAS-LIQUID JET-PUMP REACTOR
6
作者 张勇 戴干策 陈敏恒 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 1990年第1期104-111,共8页
It is found that the reactor has four types of flow regimes:a,b,c,and d,of which b is desirable inoperation.Therefore it is essential to find the criteria for flow regime transitions.On the basis of momen-tum,energy a... It is found that the reactor has four types of flow regimes:a,b,c,and d,of which b is desirable inoperation.Therefore it is essential to find the criteria for flow regime transitions.On the basis of momen-tum,energy and mass balance principles,theoretical criteria are obtained and agree well with the experi-mental results,which can be expressed 展开更多
关键词 AGREE regime TRANSITIONS desirable nozzle HYDRODYNAMIC THROAT mixing MOMENTUM EMULSION
下载PDF
Tilt adjustment for a portable absolute atomic gravimeter
7
作者 谢宏泰 陈斌 +3 位作者 龙金宝 薛春 陈泺侃 陈帅 《Chinese Physics B》 SCIE EI CAS CSCD 2020年第7期295-299,共5页
For an atomic gravimeter,the measured value of the Earth’s gravity acceleration g is the projection of the local gravity on the direction of Raman laser beams.To accurately measure the g,the Raman laser beams should ... For an atomic gravimeter,the measured value of the Earth’s gravity acceleration g is the projection of the local gravity on the direction of Raman laser beams.To accurately measure the g,the Raman laser beams should be parallel to the g direction.We analyze the tilt effect of the Raman beams on g measurement and present a general method for the tilt adjustment.The systematic error caused by the tilt angle is evaluated as 0(+0,0.8)µGal(1µGal=10 nm/s^2)and the drift is also compensated in real time.Our method is especially suitable for the portable atomic gravimeter which focuses on the mobility and field applications. 展开更多
关键词 atomic gravimeter systematic error tilt adjustment STABILITY
下载PDF
Enzymatic Method for Rapid Determination of Oxalic Acid in Bleaching Filtrates from the Pulp and Paper Industry
8
作者 洪枫 SJ(O|¨)DE Anders +1 位作者 NILVEBRANT Nils-Olof J(O|¨)NSSON Leif J 《Journal of Donghua University(English Edition)》 EI CAS 2005年第5期64-68,共5页
Bleaching with oxygen-containing agents and recirculation of process streams in the pulp and paper industry has increased the accumulation of oxalic acid and danger for precipitation of calcium oxalate encrusts, scali... Bleaching with oxygen-containing agents and recirculation of process streams in the pulp and paper industry has increased the accumulation of oxalic acid and danger for precipitation of calcium oxalate encrusts, scaling. Analysis and control of oxalic acid in bleaching filtrates is therefore becoming increasingly important in the pulp and paper industry.Chromatographic methods, such as IC and HPLC, are generally more time-consuming but are valuable as standard methods for determination of oxalic acid. However, the instrumentation needed is expensive and stationary. In this study, an enzymatic method based on oxalate oxidase and peroxidase was developed to determine oxalic acid in authentic bleaching filtrates using a spectrophotometer. The results showed that bleaching filtrates contain some compounds interfering with the enzymatic method.Pretreatment of the samples with activated charcoal was a successful approach for decreasing problems with interference. By using dilution followed by charcoal treatment, the results obtained from five bleaching filtrates with the colorimetric method correlated very well with those obtained using IC. This study offers a selective, fast and mobile analysis method to determine oxalic acid in bleaching filtrates from the pulp and paper industry. The convenient enzyme-based method improves the possibilities for control of critical oxalic acid concentrations in closed-loop bleaching streams. 展开更多
关键词 草酸 氧化酶 比色分析 活性炭 造纸工业 漂白滤液
下载PDF