Compact atomic gravimeters are the potential next generation precision instruments for gravity survey from fundamental research to broad field applications.We report the calibration results of our home build compact a...Compact atomic gravimeters are the potential next generation precision instruments for gravity survey from fundamental research to broad field applications.We report the calibration results of our home build compact absolute atomic gravimeter USTC-AG02 at Changping Campus,the National Institute of Metrology(NIM),China in January 2019.The sensitivity of the atomic gravimeter reaches 35.5μGal/√Hz(1μGal=1×10-8 m/s2)and its long-term stability reaches 0.8μGal for averaging over 4000 seconds.Considering the statistical uncertainty,the dominant instrumental systematic errors and environmental effects are evaluated and corrected within a total uncertainty(2σ)of 15.3μGal.After compared with the reference g value given by the corner cube gravimeter NIM-3A,the atomic gravimeter USTC-AG02 reaches the degree of equivalence of 3.7μGal.展开更多
Screening similar historical fault-free candidate data would greatly affect the effectiveness of fault detection results based on principal component analysis(PCA).In order to find out the candidate data,this study co...Screening similar historical fault-free candidate data would greatly affect the effectiveness of fault detection results based on principal component analysis(PCA).In order to find out the candidate data,this study compares unweighted and weighted similarity factors(SFs),which measure the similarity of the principal component subspace corresponding to the first k main components of two datasets.The fault detection employs the principal component subspace corresponding to the current measured data and the historical fault-free data.From the historical fault-free database,the load parameters are employed to locate the candidate data similar to the current operating data.Fault detection method for air conditioning systems is based on principal component.The results show that the weighted principal component SF can improve the effects of the fault-free detection and the fault detection.Compared with the unweighted SF,the average fault-free detection rate of the weighted SF is 17.33%higher than that of the unweighted,and the average fault detection rate is 7.51%higher than unweighted.展开更多
Although Morison equation is often applied for simulating hydrodynamic force of marine structure, it may give poor results when non-linear behavior is severe or random wave is encountered. This leads to some modificat...Although Morison equation is often applied for simulating hydrodynamic force of marine structure, it may give poor results when non-linear behavior is severe or random wave is encountered. This leads to some modifications of Morison equation or other methods for predicting hydrodynamic force. One of them is the system identification technique. In this paper, NARMAX model theory is firstly used to identify the hydrodynamic system of heave damping plates, which are commonly installed on spar platform. Both linear and non-linear models are obtained. The comparisons between the predieted results and measured data indicate that NARMAX model can predict hydrodynamic force of a heave damping plate very well. The measured data for identification originate from forced oscillation tests, which are random records with given spectrum. The forced oscillation forms in experiment also contain simple harmonic, multi-frequency ones.展开更多
Principal component analysis(PCA)has been already employed for fault detection of air conditioning systems.The sliding window,which is composed of some parameters satisfying with thermal load balance,can select the ta...Principal component analysis(PCA)has been already employed for fault detection of air conditioning systems.The sliding window,which is composed of some parameters satisfying with thermal load balance,can select the target historical fault-free reference data as the template which is similar to the current snapshot data.The size of sliding window is usually given according to empirical values,while the influence of different sizes of sliding windows on fault detection of an air conditioning system is not further studied.The air conditioning system is a dynamic response process,and the operating parameters change with the change of the load,while the response of the controller is delayed.In a variable air volume(VAV)air conditioning system controlled by the total air volume method,in order to ensure sufficient response time,30 data points are selected first,and then their multiples are selected.Three different sizes of sliding windows with 30,60 and 90 data points are applied to compare the fault detection effect in this paper.The results show that if the size of the sliding window is 60 data points,the average fault-free detection ratio is 80.17%in fault-free testing days,and the average fault detection ratio is 88.47%in faulty testing days.展开更多
With the development of the technology of the Internet of Things,more and more operational data can be collected from air conditioning systems.Unfortunately,the most of existing air conditioning controllers mainly pro...With the development of the technology of the Internet of Things,more and more operational data can be collected from air conditioning systems.Unfortunately,the most of existing air conditioning controllers mainly provide controlling functions more than storing,processing or computing the measured data.This study develops an online fault detection configuration on the equipment side of air conditioning systems to realize these functions.Modbus communication is served to collect real-time operational data.The calculating programs are embedded to identify whether the measured signals exceed their limits or not,and to detect if sensor reading is frozen and other faults in relation to the operational performance are generated or not.The online fault detection configuration is tested on an actual variable-air-volume(VAV)air handling unit(AHU).The results show that the time ratio of fault detection exceeds 95.00%,which means that the configuration exhibits an acceptable fault detection effect.展开更多
It is found that the reactor has four types of flow regimes:a,b,c,and d,of which b is desirable inoperation.Therefore it is essential to find the criteria for flow regime transitions.On the basis of momen-tum,energy a...It is found that the reactor has four types of flow regimes:a,b,c,and d,of which b is desirable inoperation.Therefore it is essential to find the criteria for flow regime transitions.On the basis of momen-tum,energy and mass balance principles,theoretical criteria are obtained and agree well with the experi-mental results,which can be expressed展开更多
For an atomic gravimeter,the measured value of the Earth’s gravity acceleration g is the projection of the local gravity on the direction of Raman laser beams.To accurately measure the g,the Raman laser beams should ...For an atomic gravimeter,the measured value of the Earth’s gravity acceleration g is the projection of the local gravity on the direction of Raman laser beams.To accurately measure the g,the Raman laser beams should be parallel to the g direction.We analyze the tilt effect of the Raman beams on g measurement and present a general method for the tilt adjustment.The systematic error caused by the tilt angle is evaluated as 0(+0,0.8)µGal(1µGal=10 nm/s^2)and the drift is also compensated in real time.Our method is especially suitable for the portable atomic gravimeter which focuses on the mobility and field applications.展开更多
Bleaching with oxygen-containing agents and recirculation of process streams in the pulp and paper industry has increased the accumulation of oxalic acid and danger for precipitation of calcium oxalate encrusts, scali...Bleaching with oxygen-containing agents and recirculation of process streams in the pulp and paper industry has increased the accumulation of oxalic acid and danger for precipitation of calcium oxalate encrusts, scaling. Analysis and control of oxalic acid in bleaching filtrates is therefore becoming increasingly important in the pulp and paper industry. Chromatographic methods, such as IC and HPLC, are generally more time-consuming but are valuable as standard methods for determination of oxalic acid. However, the instrumentation needed is expensive and stationary. In this study, an enzymatic method based on oxalate oxidase and peroxidase was developed to determine oxalic acid in authentic bleaching filtrates using a spectrophotometer. The results showed that bleaching filtrates contain some compounds interfering with the enzymatic method. Pretreatment of the samples with activated charcoal was a successful approach for decreasing problems with interference. By using dilution followed by charcoal treatment, the results obtained from five bleaching filtrates with the colorimetric method correlated very well with those obtained using IC. This study offers a selective, fast and mobile analysis method to determine oxalic acid in bleaching fiRrates from the pulp and paper industry, The convenient enzyme-based method improves the possibilities for control of critical oxalic acid concentrations in closed-loop bleaching streams.展开更多
基金Project supported by the National Key R&D Program of China(Grant No.2016YFA0301601)the National Natural Science Foundation of China(Grant No.11674301)+1 种基金Anhui Initiative in Quantum Information Technologies,China(Grant No.AHY120000)Shanghai Municipal Science and Technology Major Project,China(Grant No.2019SHZDZX01).
文摘Compact atomic gravimeters are the potential next generation precision instruments for gravity survey from fundamental research to broad field applications.We report the calibration results of our home build compact absolute atomic gravimeter USTC-AG02 at Changping Campus,the National Institute of Metrology(NIM),China in January 2019.The sensitivity of the atomic gravimeter reaches 35.5μGal/√Hz(1μGal=1×10-8 m/s2)and its long-term stability reaches 0.8μGal for averaging over 4000 seconds.Considering the statistical uncertainty,the dominant instrumental systematic errors and environmental effects are evaluated and corrected within a total uncertainty(2σ)of 15.3μGal.After compared with the reference g value given by the corner cube gravimeter NIM-3A,the atomic gravimeter USTC-AG02 reaches the degree of equivalence of 3.7μGal.
基金Research Project of China Ship Development and Design Center。
文摘Screening similar historical fault-free candidate data would greatly affect the effectiveness of fault detection results based on principal component analysis(PCA).In order to find out the candidate data,this study compares unweighted and weighted similarity factors(SFs),which measure the similarity of the principal component subspace corresponding to the first k main components of two datasets.The fault detection employs the principal component subspace corresponding to the current measured data and the historical fault-free data.From the historical fault-free database,the load parameters are employed to locate the candidate data similar to the current operating data.Fault detection method for air conditioning systems is based on principal component.The results show that the weighted principal component SF can improve the effects of the fault-free detection and the fault detection.Compared with the unweighted SF,the average fault-free detection rate of the weighted SF is 17.33%higher than that of the unweighted,and the average fault detection rate is 7.51%higher than unweighted.
文摘Although Morison equation is often applied for simulating hydrodynamic force of marine structure, it may give poor results when non-linear behavior is severe or random wave is encountered. This leads to some modifications of Morison equation or other methods for predicting hydrodynamic force. One of them is the system identification technique. In this paper, NARMAX model theory is firstly used to identify the hydrodynamic system of heave damping plates, which are commonly installed on spar platform. Both linear and non-linear models are obtained. The comparisons between the predieted results and measured data indicate that NARMAX model can predict hydrodynamic force of a heave damping plate very well. The measured data for identification originate from forced oscillation tests, which are random records with given spectrum. The forced oscillation forms in experiment also contain simple harmonic, multi-frequency ones.
基金Fundamental Research Funds for the Central Universities of Ministry of Education of China。
文摘Principal component analysis(PCA)has been already employed for fault detection of air conditioning systems.The sliding window,which is composed of some parameters satisfying with thermal load balance,can select the target historical fault-free reference data as the template which is similar to the current snapshot data.The size of sliding window is usually given according to empirical values,while the influence of different sizes of sliding windows on fault detection of an air conditioning system is not further studied.The air conditioning system is a dynamic response process,and the operating parameters change with the change of the load,while the response of the controller is delayed.In a variable air volume(VAV)air conditioning system controlled by the total air volume method,in order to ensure sufficient response time,30 data points are selected first,and then their multiples are selected.Three different sizes of sliding windows with 30,60 and 90 data points are applied to compare the fault detection effect in this paper.The results show that if the size of the sliding window is 60 data points,the average fault-free detection ratio is 80.17%in fault-free testing days,and the average fault detection ratio is 88.47%in faulty testing days.
基金Research Project of China Ship Development and Design Center,Wuhan,China。
文摘With the development of the technology of the Internet of Things,more and more operational data can be collected from air conditioning systems.Unfortunately,the most of existing air conditioning controllers mainly provide controlling functions more than storing,processing or computing the measured data.This study develops an online fault detection configuration on the equipment side of air conditioning systems to realize these functions.Modbus communication is served to collect real-time operational data.The calculating programs are embedded to identify whether the measured signals exceed their limits or not,and to detect if sensor reading is frozen and other faults in relation to the operational performance are generated or not.The online fault detection configuration is tested on an actual variable-air-volume(VAV)air handling unit(AHU).The results show that the time ratio of fault detection exceeds 95.00%,which means that the configuration exhibits an acceptable fault detection effect.
文摘It is found that the reactor has four types of flow regimes:a,b,c,and d,of which b is desirable inoperation.Therefore it is essential to find the criteria for flow regime transitions.On the basis of momen-tum,energy and mass balance principles,theoretical criteria are obtained and agree well with the experi-mental results,which can be expressed
基金Project supported by the National Key R&D Program of China(Grant No.2016YFA0301601)the National Natural Science Foundation of China(Grant No.11674301)+1 种基金Anhui Initiative in Quantum Information Technologies,China(Grant No.AHY120000)Shanghai Municipal Science and Technology Major Project,China(Grant No.2019SHZDZX01).
文摘For an atomic gravimeter,the measured value of the Earth’s gravity acceleration g is the projection of the local gravity on the direction of Raman laser beams.To accurately measure the g,the Raman laser beams should be parallel to the g direction.We analyze the tilt effect of the Raman beams on g measurement and present a general method for the tilt adjustment.The systematic error caused by the tilt angle is evaluated as 0(+0,0.8)µGal(1µGal=10 nm/s^2)and the drift is also compensated in real time.Our method is especially suitable for the portable atomic gravimeter which focuses on the mobility and field applications.
基金This work was supported by Vinnova and the Knowledge Foundation in Sweden.
文摘Bleaching with oxygen-containing agents and recirculation of process streams in the pulp and paper industry has increased the accumulation of oxalic acid and danger for precipitation of calcium oxalate encrusts, scaling. Analysis and control of oxalic acid in bleaching filtrates is therefore becoming increasingly important in the pulp and paper industry. Chromatographic methods, such as IC and HPLC, are generally more time-consuming but are valuable as standard methods for determination of oxalic acid. However, the instrumentation needed is expensive and stationary. In this study, an enzymatic method based on oxalate oxidase and peroxidase was developed to determine oxalic acid in authentic bleaching filtrates using a spectrophotometer. The results showed that bleaching filtrates contain some compounds interfering with the enzymatic method. Pretreatment of the samples with activated charcoal was a successful approach for decreasing problems with interference. By using dilution followed by charcoal treatment, the results obtained from five bleaching filtrates with the colorimetric method correlated very well with those obtained using IC. This study offers a selective, fast and mobile analysis method to determine oxalic acid in bleaching fiRrates from the pulp and paper industry, The convenient enzyme-based method improves the possibilities for control of critical oxalic acid concentrations in closed-loop bleaching streams.