The dynamic transmission characteristics and the sensitivities of the three stage idler gear system of the new NC power turret are studied in the paper. Considering the strongly nonlinear factors such as the periodica...The dynamic transmission characteristics and the sensitivities of the three stage idler gear system of the new NC power turret are studied in the paper. Considering the strongly nonlinear factors such as the periodically time-varying mesh stiffness, the nonlinear tooth backlash, the lump-parameter model of the gear system is developed with one rotational and two translational freedoms of each gear. The eigen-values and eigenvectors are derived and analyzed on the basis of the real modal theory. The sensitivities of natural frequencies to design parameters including supporting and meshing stiffnesses, gear masses, and moments of inertia by the direct differential method are also calculated. The results show the quantitative and qualitative impact of the parameters to the natural characteristics of the gear system. Furthermore, the periodic steady state solutions are obtained by the numerical approach based on the nonlinear model. These results are employed to gain insights into the primary controlling parameters, to forecast the severity of the dynamic response, and to assess the acceptability of the gear design.展开更多
Enabling data sharing among smart grid power suppliers is a pressing challenge due to technical hurdles in verifying,storing,and synchronizing energy metering data.Access and sharing limitations are stringent for user...Enabling data sharing among smart grid power suppliers is a pressing challenge due to technical hurdles in verifying,storing,and synchronizing energy metering data.Access and sharing limitations are stringent for users,power companies,and researchers,demanding significant resources and time for permissions and verification.This paper proposes a blockchain-based architecture for secure and efficient sharing of electric energy metering data.Further,we propose a data sharing model based on evolutionary game theory.Based on the Lyapunov stability theory,the model’s evolutionary stable strategy(ESS)is analyzed.Numerical results verify the correctness and practicability of the scheme proposed in this paper,and provide a new method for realizing convenient,safe and fast data sharing.展开更多
More demand-side flexible resources(DFRs)are participating in the frequency regulation of renewable power systems,whose heterogeneous characteristics have a significant impact on the system frequency response.Conseque...More demand-side flexible resources(DFRs)are participating in the frequency regulation of renewable power systems,whose heterogeneous characteristics have a significant impact on the system frequency response.Consequently,selecting suitable DFRs poses a formidable challenge for independent system operators(ISO).In this paper,a reserve allocation methodology for heterogeneous DFRs is proposed to manage the risk of power system frequency.Firstly,a performance curve is developed to describe the cost,capacity,and response speed of DFRs.Moreover,a clustering method for multiple distributed DFRs is conducted to calculate the aggregated performance curves and uncertainty coefficients.Then,the frequency security criterion considering DFRs’performance is constructed,whose linearity makes it can be easily coupled into the system scheduling model and solved.Furthermore,a risk management model for DFRs considering frequency-chance-constraint is proposed to make a trade-off between cost and frequency security.Finally,the model is transformed into mixed integer second-order cone programming(MISOCP)and solved by the commercial solver.The proposed model is validated by the IEEE 30 and IEEE 118 bus systems.展开更多
Detection of gas decomposition products is widely used for condition diagnosis of SF6-insulated equipment because of its an- ti-electromagnetic-interference ability and high sensitivity. Previous investigations show t...Detection of gas decomposition products is widely used for condition diagnosis of SF6-insulated equipment because of its an- ti-electromagnetic-interference ability and high sensitivity. Previous investigations show that the volume of gas chamber influences the types and concentrations of SF6 decomposition products. Therefore using a newly developed dual gas chromatography (GC) detection sys- tem we investigated the discharge and decomposition of SF6 in a discharge chamber with its volume close to that of the real chambers in GIS. Tests in the chamber were performed with different applied voltage, different electrode arrangements, and different defect types. For discharge between needle-to-plane electrodes, the typical gas decomposition products are SO2F2, SO2 and S2OF10. A near linear growth with the increase of voltage duration is found in the concentration of SO2F2, whereas the growth rates of SO2 and S2OF10 concentration decrease with time. Concentrations of SO2F2, SO2 and S2OF10 at the same voltage duration decrease with the decrease of the voltage amplitude and the increase of the needle-to-plane distance. Change of the gas chamber volume affects the generation rates of SO2F2 and SO2, however not S2OF10. For insulator surface defects, the typical gas decomposition products are CF4, CS2 and SO2. Among which, the concentrations of CF4 and SO2 increase with the voltage duration almost linearly. Moreover, a new parameter that represents the degree of SF6 degradation, the SF6 deterioration ratio, is proposed. In the needle-to-plane case, SF6 deterioration ratio is positively correlated to the fitting value of an averaged discharge capacity. However, the maximum value of SF6 deterioration ratio varies with the defect type.展开更多
The understanding of the excitation mechanism of ultra high frequency (UHF) electromagnetic waves (EW) is essential for ap- plying UHF method to partial discharge (PD) detection. Since the EW induced by PD in gas insu...The understanding of the excitation mechanism of ultra high frequency (UHF) electromagnetic waves (EW) is essential for ap- plying UHF method to partial discharge (PD) detection. Since the EW induced by PD in gas insulated switchgear (GIS) contains not only transverse electromagnetic (TEM) wave, but also high-order transverse electric (TE) and high-order transverse magnetic (TM) waves, we analyzed the proportions between the TEM wave and the high order waves, as well as the influence of the PD position on this proportion, using the finite different time domain (FDTD) method. According to the unique characteristics of the waves, they are separated only ap- proximately. It is found that the high-order mode is the main component, more than 70%, of the electric field around the enclosure of GIS, and that with the increasing distance between PD source and inner conductors, the low frequency ( below about 800 MHz) component of EW decreases, but the high frequency component (above 1 GHz) increases, meanwhile the proportion of high-order components in EW could reach 77% from 70%. It concluded that the closer the PD source to the enclosure is, the easier high order EW may be excited.展开更多
The development of high-performance batteries is inseparable from the exploration of new materials.Among them,fullerene C60 as an allotrope of carbon has many unique properties that are beneficial for battery applicat...The development of high-performance batteries is inseparable from the exploration of new materials.Among them,fullerene C60 as an allotrope of carbon has many unique properties that are beneficial for battery applications,including precise structure,controllable derivatization,good solubility,and rich redox chemistry.In this review,we summarize the recent progress of fullerene-based materials in the field of rechargeable batteries and the key issues that need to be solved in the future application of fullerene.We hope this review can provide guidance and stimulate research about the applications of fullerenes in the field of energy storage.展开更多
The choice of the UHV lines depends on surface electric field of the bundle conductors.Based on existing calculation methods,the optimized charge simulation method is used to calculate the conductors' surface elec...The choice of the UHV lines depends on surface electric field of the bundle conductors.Based on existing calculation methods,the optimized charge simulation method is used to calculate the conductors' surface electrical field of±800 kV UHVDC transmission lines in this paper.During calculation,the offset distance is set as the variance of the objective function,the position and the quantity of the simulation charges are optimized with the gold section method,and the surface electrical field is calculated when the charge is in the optimal position.The result shows that the distribution of the surface electrical field and its maximal value can be calculated accurately with this method,although less number of simulation charges is used in this proposed method and the calculation is simple.展开更多
The neutral grounding mode of medium-voltage distribution network decides the reliability, overvoltage, relay protection and electrical safety. Therefore, a comprehensive consideration of the reliability, safety and e...The neutral grounding mode of medium-voltage distribution network decides the reliability, overvoltage, relay protection and electrical safety. Therefore, a comprehensive consideration of the reliability, safety and economy is particularly important for the decision of neutral grounding mode. This paper proposes a new decision method of neutral point grounding mode for mediumvoltage distribution network. The objective function is constructed for the decision according the life cycle cost. The reliability of the neutral point grounding mode is taken into account through treating the outage cost as an operating cost. The safety condition of the neutral point grounding mode is preserved as the constraint condition of decision models, so the decision method can generate the most economical and reliable scheme of neutral point grounding mode within a safe limit. The example is used to verify the feasibility and effectiveness of the decision method.展开更多
Oil-paper compound insulation has been widely used in power transformers for quite a long time because of its good performances. The insulation gradually degrades under combined thermal, electrical and chemical stress...Oil-paper compound insulation has been widely used in power transformers for quite a long time because of its good performances. The insulation gradually degrades under combined thermal, electrical and chemical stresses during routine operations, mainly because of space charges inside. This work investigated the space charge characteristics in oil-paper insulation under oil aging circumstance. New trans- former oil samples are thermally aged to obtain different aging states, and their physical and chemical properties are analyzed. New Kraft papers are dried in vacuum and fully immersed in these different aged oil samples, and three kinds of oil-paper samples are obtained. We use the pulsed electro-acoustic (PEA) method to measure space charge under both DC voltage-on and voltage-off conditions at room temperature. The effect of oil aging state on characteristics of space charge injection, accumulation, and decay is analyzed and discussed. The results show that comparing with the DC voltage-off condition, more charges are injected into samples at the interface of electrode and dielectric when DC voltage is on. When the oil-aged state gets worse, more charges are induced at both cathode and anode, more space charges are accumulated in the bulk, the area of negative charges is larger, and local electric field is distorted more seriously. Moreover, for the voltage-off condition, aged oil is good for space charge decay, and trapped positive space charges decay faster than trapped negative charges.展开更多
A novel method is introduced for preparing iron nanoparticles from iron pentacar- bonyl using an atmospheric microwave plasma. The prepared iron nanoparticles were characterized by transmission electron microscopy and...A novel method is introduced for preparing iron nanoparticles from iron pentacar- bonyl using an atmospheric microwave plasma. The prepared iron nanoparticles were characterized by transmission electron microscopy and X-ray diffraction. The results show that the size of the particles can be controlled by adjusting the microwave power and the flow rate of the carrier gas. The magnetic properties of the synthesized iron particles were studied and a saturation magnetiza- tion of ~95 emu/g was obtained. The convenient preparation process and considerable production rate were also found to be satisfactory for industrial applications.展开更多
In industry development strategy of electric vehicles, apart from concerns on the development of electric vehicles, we also need to consider the issue of charging facilities construction. Firstly, through analysis, th...In industry development strategy of electric vehicles, apart from concerns on the development of electric vehicles, we also need to consider the issue of charging facilities construction. Firstly, through analysis, this paper discusses the importance of AC charging points for electric vehicle development. By studying existing AC charging points on the market, it presents a low-cost smart AC charging system to reduce the cost investigated by power companies and operational bodies when laying of a large number of AC charging points. Compared with the conventional one, the proposed system has prominent features of low cost, small footprint and low investment.展开更多
To promote the accuracy and application of arcing time measurement for SF_6 circuit breaker in substation,five measurement methods are investigated by two cases experimentally. First,the test results of the five metho...To promote the accuracy and application of arcing time measurement for SF_6 circuit breaker in substation,five measurement methods are investigated by two cases experimentally. First,the test results of the five methods for a circuit breaker in different stages of wear and a circuit breaker with a component failure were presented. Then,the time error is analyzed by simulation.Finally,the advantage and disadvantage of these methods are discussed.展开更多
Featuring low communication requirements and high reliability,the voltage droop control method is widely adopted in the voltage source converter based multi-terminal direct current(VSC-MTDC)system for autonomous DC vo...Featuring low communication requirements and high reliability,the voltage droop control method is widely adopted in the voltage source converter based multi-terminal direct current(VSC-MTDC)system for autonomous DC voltage regulation and power-sharing.However,the traditional voltage droop control method with fixed droop gain is criticized for over-limit DC voltage deviation in case of large power disturbances,which can threaten stable operation of the entire VSCMTDC system.To tackle this problem,this paper proposes an adaptive reference power based voltage droop control method,which changes the reference power to compensate the power deviation for droop-controlled voltage source converters(VSCs).Besides retaining the merits of the traditional voltage droop control method,both DC voltage deviation reduction and power distribution improvement can be achieved by utilizing local information and a specific control factor in the proposed method.Basic principles and key features of the proposed method are described.Detailed analyses on the effects of the control factor on DC voltage deviation and imbalanced power-sharing are discussed,and the selection principle of the control factor is proposed.Finally,the effectiveness of the proposed method is validated by the simulations on a five-terminal VSC based high-voltage direct current(VSC-HVDC)system.展开更多
In this paper,the influence of ammonia admixture on argon discharge properties is investigated.Electrical measurements,as well as ten-nanoseconds-exposure photographs taken by an intensified charge-coupled device(ICCD...In this paper,the influence of ammonia admixture on argon discharge properties is investigated.Electrical measurements,as well as ten-nanoseconds-exposure photographs taken by an intensified charge-coupled device(ICCD)camera,are employed to confirm the existence of atmospheric pressure glow discharge(APGD)in Ar/NH3mixture.The breakdown voltage and transition voltage between APGD and filamentary discharge are studied at various ammonia concentrations.The results show that a small amount of NH3can lead to APGD due to the Penning ionization of NH3molecules by metastable argon,and the breakdown voltage increases with the growth in NH3concentrations owing to the electronegative feature of NH3.The optical emission spectrum of Ar/NH3APGD is analyzed.Besides,gas temperature is estimated at 327 K by the diagnoses of the OH(A-X)(0,0)band of the spectrum.展开更多
A low voltage circuit breaker(LVCB)is an important piece of protection equipment which will switch off the fault current in a power system.The moving contact of a low voltage circuit breaker with a higher rated curren...A low voltage circuit breaker(LVCB)is an important piece of protection equipment which will switch off the fault current in a power system.The moving contact of a low voltage circuit breaker with a higher rated current consists of two parallel contacts.Therefore,the convection effect on the air arc evolution process in a two parallel contact system is analyzed.A threedimensional(3 D)magneto–hydro–dynamic(MHD)model of arc simulation is built.In this model,the anode consists of two parallel contacts and a bonding conductor.A nonlinear voltage–current density characteristic is employed to represent the near-anode and near-cathode voltage.The current density,arc voltage and currents through every contact are obtained.The influence of convection and conduction on the arc evolution process are quantitatively calculated.The displacements of the arc roots are obtained and the asymmetry of the arc root motion is analyzed.The arc evolution process of a two parallel contact system is preliminarily revealed.展开更多
With the help of smart grid technologies,a lot of electrical loads can provide demand response to support the active power balance of the grid.Compared with centralized control methods,decentralized methods reduce the...With the help of smart grid technologies,a lot of electrical loads can provide demand response to support the active power balance of the grid.Compared with centralized control methods,decentralized methods reduce the computational burden of the control center and enhance the reliability of the communication.In this paper,a novel second-order multi-agent consensus control method is proposed for load control problem.By introducing the velocity state into the model,the proposed method achieves better performance than traditional ones.Simulation results verify the effectiveness of the proposed method.展开更多
The multi-energy complementary ecosystem is an important form of the modern energy system.However,standardized evaluation criteria and the corresponding method framework have not yet been formed,resulting in unclear s...The multi-energy complementary ecosystem is an important form of the modern energy system.However,standardized evaluation criteria and the corresponding method framework have not yet been formed,resulting in unclear standards and irregular processes of its construction.To cope with this issue,a novel comprehensive evaluation framework for multi-energy complementary ecosystems is proposed in this study.First,a 5D comprehensive evaluation criteria system,including environment,economy,technology,safety and systematicness,is constructed.Then,a novel multicriteria decision-making model integrating an analytic network process,entropy and preference-ranking organization method for enrichment evaluation under an intuitional fuzzy environment is proposed.Finally,four practical cases are used for model testing and empirical analysis.The results of the research show that the unit cost of the energy supply and the internal rate of return indexes have the highest weights of 0.142 and 0.010,respectively.It means that they are the focus in the construction of a multi-energy complementary ecosystem.The net flows of four cases are 0.015,0.123,-0.132 and-0.005,indicating that cases with a variety of energy supply forms and using intelligent management and control platforms to achieve cold,heat and electrical coupling have more advantages.展开更多
Improving the restoration efficiency of a distribution system is essential to enhance the ability of power systems to deal with extreme events.The distribution system restoration(DSR)depends on the interaction among t...Improving the restoration efficiency of a distribution system is essential to enhance the ability of power systems to deal with extreme events.The distribution system restoration(DSR)depends on the interaction among the electric network(EN),cyber network(CN),and traffic network(TN).However,the coordination of these three networks and codispatching of multiple recovery resources have been mostly neglected.This paper proposes a novel DSR framework,which is formulated as a mixed-integer linear programming(MILP)problem.The failures in cyber lines result in cyber blind areas,which restrict the normal operation of remote-controlled switches.To accelerate the recovery process,multiple recovery resources are utilized including electric maintenance crews(EMCs),cyber maintenance crews(CMCs),and emergency communication vehicles(ECVs).Specifically,CMCs and ECVs restore the cyber function of switches in cooperation,and EMCs repair damaged electric lines.The travel time of these three dispatchable resources is determined by TN.The effectiveness and superiority of the proposed framework are verified on the modified IEEE 33-node and 123-node test systems.展开更多
A hierarchically correlated equilibrium Q-learning(HCEQ)algorithm for reactive power optimization that considers carbon emission on the grid-side as an optimization objective,is proposed here.Based on the multi-area d...A hierarchically correlated equilibrium Q-learning(HCEQ)algorithm for reactive power optimization that considers carbon emission on the grid-side as an optimization objective,is proposed here.Based on the multi-area decentralized collaborative framework,the controllable variables in each region are divided into several optimization layers,which is an effective method for solving the limitations posed by dimensionality.The HCEQ provides constant information on the interaction between the state-action value function matrices,as well as on the cooperative game equilibrium among agents in each region.After acquiring the optimal value function matrix in the pre-learning process,HCEQ is able to quickly achieve an optimal solution online.Simulation of the IEEE 57-bus system is performed,which demonstrates that the proposed algorithm can effectively solve multi-area decentralized collaborative reactive power optimization,with the desired global search capabilities and convergence speed.展开更多
Data centers(DCs)are highly energy-intensive facilities,where about 30%–50%of the power consumed is attributable to the cooling of information technology equipment.This makes liquid cooling,especially in twophase mod...Data centers(DCs)are highly energy-intensive facilities,where about 30%–50%of the power consumed is attributable to the cooling of information technology equipment.This makes liquid cooling,especially in twophase mode,as an alternative to air cooling for the microprocessors in servers of interest.The need to meet the increased power density of server racks in high-performance DCs,along with the push towards lower global warming potential(GWP)refrigerants due to environmental concerns,has motivated research on the selection of two-phase heat transfer fluids for cooling servers while simultaneously recovering waste heat.With this regard,a heat pump-assisted absorption chiller(HPAAC)system for recovering waste heat in DCs with an on-chip twophase cooling loop driven by the compressor is proposed in the present paper and the low GWP hydrofluoroolefin refrigerants,including R1224yd(Z),R1233zd(E),R1234yf,R1234ze(E),R1234ze(Z),R1243zf and R1336mzz(Z),are evaluated and compared against R245fa as server coolant.For theHPAAC system,beginning with the development of energy and economic models,the performance is analyzed through both a parametric study and optimization using the coefficient of performance(COP),energy saving ratio(ESR),payback period(PBP)and net present value(NPV)as thermo-economic indicators.Using a standard vapor compression cooling system as a benchmark,the results indicate that with the evaporation temperature between 50℃and 70℃and the subcooling degree ranging from5℃to 15°C,R1233zd(E)with moderate compressor suction pressure and pressure ratio is the best refrigerant for the HPAAC systemwhile R1234yf performs the worst.More importantly,R1233zd(E)is also superior to R245fa based on thermo-economic performance,especially under work conditions with relatively lower evaporation temperature as well as subcooling degree.Under the given working conditions,the overall COP,ESR,NPV,and PBP of R1233zd(E)HPAAC with optimum subcooling degree range from4.99 to 11.27,25.53 to 64.59,1.13 to 4.10×10^(7) CNY and 5.77 to 2.22 years,respectively.Besides,the thermo-economic performance of R1233zd(E)HPAAC under optimum working conditions in terms of subcooling degree varying with the evaporation temperature is also investigated.展开更多
文摘The dynamic transmission characteristics and the sensitivities of the three stage idler gear system of the new NC power turret are studied in the paper. Considering the strongly nonlinear factors such as the periodically time-varying mesh stiffness, the nonlinear tooth backlash, the lump-parameter model of the gear system is developed with one rotational and two translational freedoms of each gear. The eigen-values and eigenvectors are derived and analyzed on the basis of the real modal theory. The sensitivities of natural frequencies to design parameters including supporting and meshing stiffnesses, gear masses, and moments of inertia by the direct differential method are also calculated. The results show the quantitative and qualitative impact of the parameters to the natural characteristics of the gear system. Furthermore, the periodic steady state solutions are obtained by the numerical approach based on the nonlinear model. These results are employed to gain insights into the primary controlling parameters, to forecast the severity of the dynamic response, and to assess the acceptability of the gear design.
文摘Enabling data sharing among smart grid power suppliers is a pressing challenge due to technical hurdles in verifying,storing,and synchronizing energy metering data.Access and sharing limitations are stringent for users,power companies,and researchers,demanding significant resources and time for permissions and verification.This paper proposes a blockchain-based architecture for secure and efficient sharing of electric energy metering data.Further,we propose a data sharing model based on evolutionary game theory.Based on the Lyapunov stability theory,the model’s evolutionary stable strategy(ESS)is analyzed.Numerical results verify the correctness and practicability of the scheme proposed in this paper,and provide a new method for realizing convenient,safe and fast data sharing.
基金supported by the Key Science and Technology Project of China Southern Power Grid Corporation(Grant No.090000KK52220020)。
文摘More demand-side flexible resources(DFRs)are participating in the frequency regulation of renewable power systems,whose heterogeneous characteristics have a significant impact on the system frequency response.Consequently,selecting suitable DFRs poses a formidable challenge for independent system operators(ISO).In this paper,a reserve allocation methodology for heterogeneous DFRs is proposed to manage the risk of power system frequency.Firstly,a performance curve is developed to describe the cost,capacity,and response speed of DFRs.Moreover,a clustering method for multiple distributed DFRs is conducted to calculate the aggregated performance curves and uncertainty coefficients.Then,the frequency security criterion considering DFRs’performance is constructed,whose linearity makes it can be easily coupled into the system scheduling model and solved.Furthermore,a risk management model for DFRs considering frequency-chance-constraint is proposed to make a trade-off between cost and frequency security.Finally,the model is transformed into mixed integer second-order cone programming(MISOCP)and solved by the commercial solver.The proposed model is validated by the IEEE 30 and IEEE 118 bus systems.
基金Project supported by International Cooperation Project in Shaanxi Province of China (2012KW-01)
文摘Detection of gas decomposition products is widely used for condition diagnosis of SF6-insulated equipment because of its an- ti-electromagnetic-interference ability and high sensitivity. Previous investigations show that the volume of gas chamber influences the types and concentrations of SF6 decomposition products. Therefore using a newly developed dual gas chromatography (GC) detection sys- tem we investigated the discharge and decomposition of SF6 in a discharge chamber with its volume close to that of the real chambers in GIS. Tests in the chamber were performed with different applied voltage, different electrode arrangements, and different defect types. For discharge between needle-to-plane electrodes, the typical gas decomposition products are SO2F2, SO2 and S2OF10. A near linear growth with the increase of voltage duration is found in the concentration of SO2F2, whereas the growth rates of SO2 and S2OF10 concentration decrease with time. Concentrations of SO2F2, SO2 and S2OF10 at the same voltage duration decrease with the decrease of the voltage amplitude and the increase of the needle-to-plane distance. Change of the gas chamber volume affects the generation rates of SO2F2 and SO2, however not S2OF10. For insulator surface defects, the typical gas decomposition products are CF4, CS2 and SO2. Among which, the concentrations of CF4 and SO2 increase with the voltage duration almost linearly. Moreover, a new parameter that represents the degree of SF6 degradation, the SF6 deterioration ratio, is proposed. In the needle-to-plane case, SF6 deterioration ratio is positively correlated to the fitting value of an averaged discharge capacity. However, the maximum value of SF6 deterioration ratio varies with the defect type.
基金Project supported by National High-tech Research and Development Program of China (863 Program) (2011AA05A121)
文摘The understanding of the excitation mechanism of ultra high frequency (UHF) electromagnetic waves (EW) is essential for ap- plying UHF method to partial discharge (PD) detection. Since the EW induced by PD in gas insulated switchgear (GIS) contains not only transverse electromagnetic (TEM) wave, but also high-order transverse electric (TE) and high-order transverse magnetic (TM) waves, we analyzed the proportions between the TEM wave and the high order waves, as well as the influence of the PD position on this proportion, using the finite different time domain (FDTD) method. According to the unique characteristics of the waves, they are separated only ap- proximately. It is found that the high-order mode is the main component, more than 70%, of the electric field around the enclosure of GIS, and that with the increasing distance between PD source and inner conductors, the low frequency ( below about 800 MHz) component of EW decreases, but the high frequency component (above 1 GHz) increases, meanwhile the proportion of high-order components in EW could reach 77% from 70%. It concluded that the closer the PD source to the enclosure is, the easier high order EW may be excited.
基金supported by the fund from the National Key R&D Program of China(2018YFB0905300,2018YFB0905305)the Shenzhen Power Supply Co.,Ltd.research fund for Economic analysis and key technology research of lithium iron phosphate battery system for electric energy storage(090000KK52190063)the National Natural Science Foundation of China(Nos.21975087,U1966214,51902116,21925104,and 51672093)。
文摘The development of high-performance batteries is inseparable from the exploration of new materials.Among them,fullerene C60 as an allotrope of carbon has many unique properties that are beneficial for battery applications,including precise structure,controllable derivatization,good solubility,and rich redox chemistry.In this review,we summarize the recent progress of fullerene-based materials in the field of rechargeable batteries and the key issues that need to be solved in the future application of fullerene.We hope this review can provide guidance and stimulate research about the applications of fullerenes in the field of energy storage.
基金Project Supported by National Natural Science Foundation of China(90510015).
文摘The choice of the UHV lines depends on surface electric field of the bundle conductors.Based on existing calculation methods,the optimized charge simulation method is used to calculate the conductors' surface electrical field of±800 kV UHVDC transmission lines in this paper.During calculation,the offset distance is set as the variance of the objective function,the position and the quantity of the simulation charges are optimized with the gold section method,and the surface electrical field is calculated when the charge is in the optimal position.The result shows that the distribution of the surface electrical field and its maximal value can be calculated accurately with this method,although less number of simulation charges is used in this proposed method and the calculation is simple.
文摘The neutral grounding mode of medium-voltage distribution network decides the reliability, overvoltage, relay protection and electrical safety. Therefore, a comprehensive consideration of the reliability, safety and economy is particularly important for the decision of neutral grounding mode. This paper proposes a new decision method of neutral point grounding mode for mediumvoltage distribution network. The objective function is constructed for the decision according the life cycle cost. The reliability of the neutral point grounding mode is taken into account through treating the outage cost as an operating cost. The safety condition of the neutral point grounding mode is preserved as the constraint condition of decision models, so the decision method can generate the most economical and reliable scheme of neutral point grounding mode within a safe limit. The example is used to verify the feasibility and effectiveness of the decision method.
基金Project supported by China National Fund for Distinguished Young Scientists (51125029)National High-tech Research and Development Program of China (863 Program) (2007AA04Z411)
文摘Oil-paper compound insulation has been widely used in power transformers for quite a long time because of its good performances. The insulation gradually degrades under combined thermal, electrical and chemical stresses during routine operations, mainly because of space charges inside. This work investigated the space charge characteristics in oil-paper insulation under oil aging circumstance. New trans- former oil samples are thermally aged to obtain different aging states, and their physical and chemical properties are analyzed. New Kraft papers are dried in vacuum and fully immersed in these different aged oil samples, and three kinds of oil-paper samples are obtained. We use the pulsed electro-acoustic (PEA) method to measure space charge under both DC voltage-on and voltage-off conditions at room temperature. The effect of oil aging state on characteristics of space charge injection, accumulation, and decay is analyzed and discussed. The results show that comparing with the DC voltage-off condition, more charges are injected into samples at the interface of electrode and dielectric when DC voltage is on. When the oil-aged state gets worse, more charges are induced at both cathode and anode, more space charges are accumulated in the bulk, the area of negative charges is larger, and local electric field is distorted more seriously. Moreover, for the voltage-off condition, aged oil is good for space charge decay, and trapped positive space charges decay faster than trapped negative charges.
基金supported by National Natural Science Foundation of China(No.51177085)the State Key Laboratory Foundation of Power System of China(No.SKLD10M07)China Postdoctoral Science Foundation(No.2013M540942)
文摘A novel method is introduced for preparing iron nanoparticles from iron pentacar- bonyl using an atmospheric microwave plasma. The prepared iron nanoparticles were characterized by transmission electron microscopy and X-ray diffraction. The results show that the size of the particles can be controlled by adjusting the microwave power and the flow rate of the carrier gas. The magnetic properties of the synthesized iron particles were studied and a saturation magnetiza- tion of ~95 emu/g was obtained. The convenient preparation process and considerable production rate were also found to be satisfactory for industrial applications.
文摘In industry development strategy of electric vehicles, apart from concerns on the development of electric vehicles, we also need to consider the issue of charging facilities construction. Firstly, through analysis, this paper discusses the importance of AC charging points for electric vehicle development. By studying existing AC charging points on the market, it presents a low-cost smart AC charging system to reduce the cost investigated by power companies and operational bodies when laying of a large number of AC charging points. Compared with the conventional one, the proposed system has prominent features of low cost, small footprint and low investment.
基金Project Supported by the Technique Project of China Southern Power Grid Co.,Ltd.(20142001342)
文摘To promote the accuracy and application of arcing time measurement for SF_6 circuit breaker in substation,five measurement methods are investigated by two cases experimentally. First,the test results of the five methods for a circuit breaker in different stages of wear and a circuit breaker with a component failure were presented. Then,the time error is analyzed by simulation.Finally,the advantage and disadvantage of these methods are discussed.
基金supported by the Key Science and Technology Projects of China Southern Power Grid Corporation(No.090000KK52180116)National Natural Science Foundation of China(No.51807135)。
文摘Featuring low communication requirements and high reliability,the voltage droop control method is widely adopted in the voltage source converter based multi-terminal direct current(VSC-MTDC)system for autonomous DC voltage regulation and power-sharing.However,the traditional voltage droop control method with fixed droop gain is criticized for over-limit DC voltage deviation in case of large power disturbances,which can threaten stable operation of the entire VSCMTDC system.To tackle this problem,this paper proposes an adaptive reference power based voltage droop control method,which changes the reference power to compensate the power deviation for droop-controlled voltage source converters(VSCs).Besides retaining the merits of the traditional voltage droop control method,both DC voltage deviation reduction and power distribution improvement can be achieved by utilizing local information and a specific control factor in the proposed method.Basic principles and key features of the proposed method are described.Detailed analyses on the effects of the control factor on DC voltage deviation and imbalanced power-sharing are discussed,and the selection principle of the control factor is proposed.Finally,the effectiveness of the proposed method is validated by the simulations on a five-terminal VSC based high-voltage direct current(VSC-HVDC)system.
基金Project supported by China National Fund for Distinguished Young Scientists(51125029)
文摘In this paper,the influence of ammonia admixture on argon discharge properties is investigated.Electrical measurements,as well as ten-nanoseconds-exposure photographs taken by an intensified charge-coupled device(ICCD)camera,are employed to confirm the existence of atmospheric pressure glow discharge(APGD)in Ar/NH3mixture.The breakdown voltage and transition voltage between APGD and filamentary discharge are studied at various ammonia concentrations.The results show that a small amount of NH3can lead to APGD due to the Penning ionization of NH3molecules by metastable argon,and the breakdown voltage increases with the growth in NH3concentrations owing to the electronegative feature of NH3.The optical emission spectrum of Ar/NH3APGD is analyzed.Besides,gas temperature is estimated at 327 K by the diagnoses of the OH(A-X)(0,0)band of the spectrum.
基金supported by the Natural Science Foundation of Shaanxi Province of China(No.2017ZDJC-16)Shenzhen Power Supply Co.Ltd(No.SZKJXM20170480).
文摘A low voltage circuit breaker(LVCB)is an important piece of protection equipment which will switch off the fault current in a power system.The moving contact of a low voltage circuit breaker with a higher rated current consists of two parallel contacts.Therefore,the convection effect on the air arc evolution process in a two parallel contact system is analyzed.A threedimensional(3 D)magneto–hydro–dynamic(MHD)model of arc simulation is built.In this model,the anode consists of two parallel contacts and a bonding conductor.A nonlinear voltage–current density characteristic is employed to represent the near-anode and near-cathode voltage.The current density,arc voltage and currents through every contact are obtained.The influence of convection and conduction on the arc evolution process are quantitatively calculated.The displacements of the arc roots are obtained and the asymmetry of the arc root motion is analyzed.The arc evolution process of a two parallel contact system is preliminarily revealed.
基金supported by Science and Technology Project of China Southern Power Grid Corporation(090000KK52190230).
文摘With the help of smart grid technologies,a lot of electrical loads can provide demand response to support the active power balance of the grid.Compared with centralized control methods,decentralized methods reduce the computational burden of the control center and enhance the reliability of the communication.In this paper,a novel second-order multi-agent consensus control method is proposed for load control problem.By introducing the velocity state into the model,the proposed method achieves better performance than traditional ones.Simulation results verify the effectiveness of the proposed method.
基金supported by the second batch of the soft subject research project of China Southern Power Grid Corporation in 2022,‘Exploring the construction path of multi energy complementary ecosystem of industrial parks in Qianhai’(XNXM_20221209003).
文摘The multi-energy complementary ecosystem is an important form of the modern energy system.However,standardized evaluation criteria and the corresponding method framework have not yet been formed,resulting in unclear standards and irregular processes of its construction.To cope with this issue,a novel comprehensive evaluation framework for multi-energy complementary ecosystems is proposed in this study.First,a 5D comprehensive evaluation criteria system,including environment,economy,technology,safety and systematicness,is constructed.Then,a novel multicriteria decision-making model integrating an analytic network process,entropy and preference-ranking organization method for enrichment evaluation under an intuitional fuzzy environment is proposed.Finally,four practical cases are used for model testing and empirical analysis.The results of the research show that the unit cost of the energy supply and the internal rate of return indexes have the highest weights of 0.142 and 0.010,respectively.It means that they are the focus in the construction of a multi-energy complementary ecosystem.The net flows of four cases are 0.015,0.123,-0.132 and-0.005,indicating that cases with a variety of energy supply forms and using intelligent management and control platforms to achieve cold,heat and electrical coupling have more advantages.
基金supported by the National Natural Science Foundation of China(No.52007016).
文摘Improving the restoration efficiency of a distribution system is essential to enhance the ability of power systems to deal with extreme events.The distribution system restoration(DSR)depends on the interaction among the electric network(EN),cyber network(CN),and traffic network(TN).However,the coordination of these three networks and codispatching of multiple recovery resources have been mostly neglected.This paper proposes a novel DSR framework,which is formulated as a mixed-integer linear programming(MILP)problem.The failures in cyber lines result in cyber blind areas,which restrict the normal operation of remote-controlled switches.To accelerate the recovery process,multiple recovery resources are utilized including electric maintenance crews(EMCs),cyber maintenance crews(CMCs),and emergency communication vehicles(ECVs).Specifically,CMCs and ECVs restore the cyber function of switches in cooperation,and EMCs repair damaged electric lines.The travel time of these three dispatchable resources is determined by TN.The effectiveness and superiority of the proposed framework are verified on the modified IEEE 33-node and 123-node test systems.
基金supported in part by National Key Basic Research Program of China(973 Program:2013CB228205)National Natural Science Foundation of China(51177051,51477055).
文摘A hierarchically correlated equilibrium Q-learning(HCEQ)algorithm for reactive power optimization that considers carbon emission on the grid-side as an optimization objective,is proposed here.Based on the multi-area decentralized collaborative framework,the controllable variables in each region are divided into several optimization layers,which is an effective method for solving the limitations posed by dimensionality.The HCEQ provides constant information on the interaction between the state-action value function matrices,as well as on the cooperative game equilibrium among agents in each region.After acquiring the optimal value function matrix in the pre-learning process,HCEQ is able to quickly achieve an optimal solution online.Simulation of the IEEE 57-bus system is performed,which demonstrates that the proposed algorithm can effectively solve multi-area decentralized collaborative reactive power optimization,with the desired global search capabilities and convergence speed.
基金supported by the Key Science and Technology Project of China Southern Grid Co.,Ltd.(No.090000KK52220020).
文摘Data centers(DCs)are highly energy-intensive facilities,where about 30%–50%of the power consumed is attributable to the cooling of information technology equipment.This makes liquid cooling,especially in twophase mode,as an alternative to air cooling for the microprocessors in servers of interest.The need to meet the increased power density of server racks in high-performance DCs,along with the push towards lower global warming potential(GWP)refrigerants due to environmental concerns,has motivated research on the selection of two-phase heat transfer fluids for cooling servers while simultaneously recovering waste heat.With this regard,a heat pump-assisted absorption chiller(HPAAC)system for recovering waste heat in DCs with an on-chip twophase cooling loop driven by the compressor is proposed in the present paper and the low GWP hydrofluoroolefin refrigerants,including R1224yd(Z),R1233zd(E),R1234yf,R1234ze(E),R1234ze(Z),R1243zf and R1336mzz(Z),are evaluated and compared against R245fa as server coolant.For theHPAAC system,beginning with the development of energy and economic models,the performance is analyzed through both a parametric study and optimization using the coefficient of performance(COP),energy saving ratio(ESR),payback period(PBP)and net present value(NPV)as thermo-economic indicators.Using a standard vapor compression cooling system as a benchmark,the results indicate that with the evaporation temperature between 50℃and 70℃and the subcooling degree ranging from5℃to 15°C,R1233zd(E)with moderate compressor suction pressure and pressure ratio is the best refrigerant for the HPAAC systemwhile R1234yf performs the worst.More importantly,R1233zd(E)is also superior to R245fa based on thermo-economic performance,especially under work conditions with relatively lower evaporation temperature as well as subcooling degree.Under the given working conditions,the overall COP,ESR,NPV,and PBP of R1233zd(E)HPAAC with optimum subcooling degree range from4.99 to 11.27,25.53 to 64.59,1.13 to 4.10×10^(7) CNY and 5.77 to 2.22 years,respectively.Besides,the thermo-economic performance of R1233zd(E)HPAAC under optimum working conditions in terms of subcooling degree varying with the evaporation temperature is also investigated.