期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Measurement of algae PSII photosynthetic parameters using high-frequency excitation flashes 被引量:2
1
作者 石朝毅 张玉钧 +7 位作者 殷高方 赵南京 段静波 余晓娅 肖雪 甘婷婷 方丽 刘文清 《Chinese Optics Letters》 SCIE EI CAS CSCD 2014年第8期1-4,共4页
We establish a system to measure the functional absorption cross section of photosystem lI (PSII) (O-PSII) and maximum quantum yield of photochemistry in PSII (Fv/Fm). The system utilizes a sequence of high-freq... We establish a system to measure the functional absorption cross section of photosystem lI (PSII) (O-PSII) and maximum quantum yield of photochemistry in PSII (Fv/Fm). The system utilizes a sequence of high-frequency excitation flashes at microsecond intervals to induce a microsecond-level fluorescence yield curve. Parameters o-Psii and Fv/Fm are calculated by fitting the curve using nonlinear regression. Experimental results show that the relative standard deviation (RSD) of the system is less than 3%, and the correlation coefficient of Fv/Fm values measured by this system and those measured by pulse amplitude modulation method is 0.950. 展开更多
关键词 PSII Measurement of algae PSII photosynthetic parameters using high-frequency excitation flashes LEDs high
原文传递
Single-turnover and multiple-turnover measurement of phytoplankton photosynthesis parameters using variable light pulse induced fluorescence
2
作者 石朝毅 高先和 +4 位作者 殷高方 覃志松 段静波 陈双 卢军 《Chinese Optics Letters》 SCIE EI CAS CSCD 2018年第1期81-85,共5页
Using a measurement system based on fluorescence induced by variable pulse light, photosynthesis parameters of chlorella pyrenoidosa are obtained, employing single-turnover and multiple-turnover protocols under darkad... Using a measurement system based on fluorescence induced by variable pulse light, photosynthesis parameters of chlorella pyrenoidosa are obtained, employing single-turnover and multiple-turnover protocols under darkadapted and light-adapted conditions. Under the light-adapted condition,σ’PSII is larger, and F’v/F’m(ST) and F’v/F’m(MT) are smaller than those of the dark-adapted condition, but the corresponding parameters possess good linear correlations.Fm(MT), F’m(MT), Fv/Fm(MT) and F’v/F’m(MT) which are measured using the multipleturnover protocol, are larger than those of the single-turnover protocol. The linear correlation coefficient between Fm(ST) and Fm(MT) is 0.984,and Fv/Fm(MT) = 1.18 Fv/Fm(ST) The linear correlation coefficient between F’m(ST) and F’m(MT) is 0.995, and F’v/F’m(MT) = 1.36 F’v/F’m/(ST). 展开更多
关键词 Single-turnover and multiple-turnover measurement of phytoplankton photosynthesis parameters using variable light pulse induced fluorescence
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部