In this paper, a new type of pumped-storage power station with faster response speed, wider regulation range, and better stability is proposed. The operational flexible of the traditional pumped-storage power station ...In this paper, a new type of pumped-storage power station with faster response speed, wider regulation range, and better stability is proposed. The operational flexible of the traditional pumped-storage power station can be improved with variable-speed pumped-storage tech no logy. Combined with chemical en ergy storage, the failure to achieve sec on d-order response speed and the insufficient safety and reliability of pumped-storage power units could be solved. With the better solar en ergy and site resources, the in teg rated performance can be improved by an optical storage system in stalled in future pumped-storage stations. Through the characteristics analysis of the new type of pumped-storage power station, three types of optimal station locations are proposed, namely, the load concentration area, new energy concentration area, and ultrahigh- voltage direct current receiver area. Taking the new pumped-storage power station as an example, the advantages of multi-energy cooperation and joint operation are analyzed. It can be predicted that the frequency and load regulation of the power grid will be more flexible, and the service capacity to the main power grid will be much stronger in the future.展开更多
Reducing carbon emissions in the power sector is critical for transitioning to a sustainable and low-carbon future.Estimating carbon efficiency of demand side response(DSR)in the power system is an important step towa...Reducing carbon emissions in the power sector is critical for transitioning to a sustainable and low-carbon future.Estimating carbon efficiency of demand side response(DSR)in the power system is an important step towards realizing potential environmental benefits.Marginal emission factor(MEF)is an effective tool for estimating incremental changes in carbon emissions as a result of a change in demand.However,estimation methods currently used for evaluating MEF can be improved upon,specifically,by factoring in the ramp-rate constraint of generators in the fuel cost based merit order dispatch.In this paper is described a new method for MEF assessment under ramp-rate constraints;the method is then compared with two conventional estimations in a British power system.Three fuel price scenarios are used to conduct a sensitivity analysis of MEFs to fuel prices.Conclusions are drawn that can pave the way for future improvements in estimating MEF in power systems.展开更多
基金supported by the State Grid Science and Technology Project(No.SGZJ0000KXJS1800313/Title 1:Research on Key Technologies Engineering Application of Large Variable Speed Pumped Storage UnitNo.SGTYHT/17-JS-199/Title 2:Study on Transient Characteristics Analysis of Variable Speed Pumped Storage Unit and Coordination Control Technology of Network Source)
文摘In this paper, a new type of pumped-storage power station with faster response speed, wider regulation range, and better stability is proposed. The operational flexible of the traditional pumped-storage power station can be improved with variable-speed pumped-storage tech no logy. Combined with chemical en ergy storage, the failure to achieve sec on d-order response speed and the insufficient safety and reliability of pumped-storage power units could be solved. With the better solar en ergy and site resources, the in teg rated performance can be improved by an optical storage system in stalled in future pumped-storage stations. Through the characteristics analysis of the new type of pumped-storage power station, three types of optimal station locations are proposed, namely, the load concentration area, new energy concentration area, and ultrahigh- voltage direct current receiver area. Taking the new pumped-storage power station as an example, the advantages of multi-energy cooperation and joint operation are analyzed. It can be predicted that the frequency and load regulation of the power grid will be more flexible, and the service capacity to the main power grid will be much stronger in the future.
基金This work was supported in part by the Science and Technology Project of State Grid Corporation of China(No.SGTYHT/14-JS-188).
文摘Reducing carbon emissions in the power sector is critical for transitioning to a sustainable and low-carbon future.Estimating carbon efficiency of demand side response(DSR)in the power system is an important step towards realizing potential environmental benefits.Marginal emission factor(MEF)is an effective tool for estimating incremental changes in carbon emissions as a result of a change in demand.However,estimation methods currently used for evaluating MEF can be improved upon,specifically,by factoring in the ramp-rate constraint of generators in the fuel cost based merit order dispatch.In this paper is described a new method for MEF assessment under ramp-rate constraints;the method is then compared with two conventional estimations in a British power system.Three fuel price scenarios are used to conduct a sensitivity analysis of MEFs to fuel prices.Conclusions are drawn that can pave the way for future improvements in estimating MEF in power systems.