期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Robust three dimensional surface contouring method with digital holography
1
作者 YUAN Cao-jin ZHAI Hong-chen +1 位作者 WANG Xiao-lei and WU Lan 《Optoelectronics Letters》 EI 2006年第6期468-470,共3页
In this paper,a digital holography system with short-coherence light source is used to record a series of holograms of a micro-object.The three dimensional reconstruction is completed by the least-square-polynomial-fi... In this paper,a digital holography system with short-coherence light source is used to record a series of holograms of a micro-object.The three dimensional reconstruction is completed by the least-square-polynomial-fitting with a series of two dimensional intensity images which are obtained through holographic reconstruction.This three dimensional reconstruction method can be used to carry out three-dimensional reconstruction of a micro-object with strong laser speckle noise,which can not be obtained from the conventional method. 展开更多
关键词 数字全息术 全息光学 短相干性光源 全息图
下载PDF
Fourier domain optical coherence tomography with ultralong depth range 被引量:2
2
作者 Zhihua DING Yi SHEN Wen BAO Peng LI 《Frontiers of Optoelectronics》 CSCD 2015年第2期163-169,共7页
The depth ranges of typical implementations of Fourier domain optical coherence tomography (FDOCT), including spectral domain OCT (SDOCT) and swept source OCT (SSOCT), are limited to several millimeters. To exte... The depth ranges of typical implementations of Fourier domain optical coherence tomography (FDOCT), including spectral domain OCT (SDOCT) and swept source OCT (SSOCT), are limited to several millimeters. To extend the depth range of current OCT systems, two novel systems with ultralong depth range were developed in this study. One is the orthogonal dispersive SDOCT (OD-SDOCT), and the other is the recirculated swept source (R-SS) interferometer/OCT. No compromise between depth range and depth resolution is required in both systems. The developed OD-SDOCT system realized the longest depth range (over 100 mm) ever achieved by SDOCT, which is ready to be modified for depth-encoded parallel imaging on multiple sites. The developed R-SS interferometer achieved submicron precision within a depth range of 30mm, holding potential in real-time contact-free on-axis metrology of complex optical sys- tems. 展开更多
关键词 optical coherence tomography (OCT) vir-tually-imaged phased array (VIPA) orthogonal dispersion swept source light recirculation parallel imaging dimen-sional metrology
原文传递
上一页 1 下一页 到第