A 15-storey K-braced reinforced concrete model frame with irregular columns, i.e., T-shaped, L-shaped, as well as +-shaped columns, was constructed and tested on the six-degree-of-freedom shaking table at the State K...A 15-storey K-braced reinforced concrete model frame with irregular columns, i.e., T-shaped, L-shaped, as well as +-shaped columns, was constructed and tested on the six-degree-of-freedom shaking table at the State Key Laboratory for Disaster Reduction in Civil Engineering in Tongji, China. Two types of earthquake records, El-Centro wave (south-north direction) and Shanghai artificial wave (SHAW) with various peak accelerations and principal-secondary sequences, were input and experimentally studied. Based on the shaking table tests and theoretical analysis, several observations can be made. The failure sequence of the model structure is brace→beam→column→joints, so that the design philosophy for several lines of defense has been achieved. Earthquake waves with different spectrums not only influence the magnitude and distribution of the earthquake force and the storey shear force, but also obviously affect the magnitude of the displacement response. The aftershock seismic response of previously damaged reinforced concrete braced frames with irregular columns possesses the equivalent elastic performance characteristic. Generally speaking, from the aspects of failure features and drift ratio, this type of reinforced concrete structure provides adequate earthquake resistance and can be promoted for use in China.展开更多
Sandwich masonry walls are widely used as energy-saving panels since the interlayer between the outer leaves can act as an insulation layer.New types of sandwich walls are continually being introduced in research and ...Sandwich masonry walls are widely used as energy-saving panels since the interlayer between the outer leaves can act as an insulation layer.New types of sandwich walls are continually being introduced in research and applications,and due to their unique bond patterns,experimental studies have been performed to investigate their mechanical properties,especially with regard to their seismic performance.In this study,three new types of sandwich masonry wall have been designed,and cyclic lateral loading tests were carried out on five specimens.The results showed that the specimens failed mainly due to slippage along the bottom cracks or the development of diagonal cracks,and the failure patterns were considerably influenced by the aspect ratio.Analysis was undertaken on the seismic response of the new walls,which included ductility,stiffness degradation and energy dissipation capacity,and no obvious difference was observed between the seismic performance of the new walls and traditional walls.Comparisons were made between the experimental results and the calculated results of the shear capacity.It is concluded that the formulas in the two Chinese codes(GB 50011 and GB 50003) are suitable for the calculation of the shear capacity for the new types of walls,and the formula in GB 50011 tends to be more conservative.展开更多
文摘A 15-storey K-braced reinforced concrete model frame with irregular columns, i.e., T-shaped, L-shaped, as well as +-shaped columns, was constructed and tested on the six-degree-of-freedom shaking table at the State Key Laboratory for Disaster Reduction in Civil Engineering in Tongji, China. Two types of earthquake records, El-Centro wave (south-north direction) and Shanghai artificial wave (SHAW) with various peak accelerations and principal-secondary sequences, were input and experimentally studied. Based on the shaking table tests and theoretical analysis, several observations can be made. The failure sequence of the model structure is brace→beam→column→joints, so that the design philosophy for several lines of defense has been achieved. Earthquake waves with different spectrums not only influence the magnitude and distribution of the earthquake force and the storey shear force, but also obviously affect the magnitude of the displacement response. The aftershock seismic response of previously damaged reinforced concrete braced frames with irregular columns possesses the equivalent elastic performance characteristic. Generally speaking, from the aspects of failure features and drift ratio, this type of reinforced concrete structure provides adequate earthquake resistance and can be promoted for use in China.
基金Key Projects of the National Science & Technology Pillar Program under Grant No. 2008BAK48B03the National Natural Science Foundation of China Under Grant No.51178340Jiangsu Qixiu Group
文摘Sandwich masonry walls are widely used as energy-saving panels since the interlayer between the outer leaves can act as an insulation layer.New types of sandwich walls are continually being introduced in research and applications,and due to their unique bond patterns,experimental studies have been performed to investigate their mechanical properties,especially with regard to their seismic performance.In this study,three new types of sandwich masonry wall have been designed,and cyclic lateral loading tests were carried out on five specimens.The results showed that the specimens failed mainly due to slippage along the bottom cracks or the development of diagonal cracks,and the failure patterns were considerably influenced by the aspect ratio.Analysis was undertaken on the seismic response of the new walls,which included ductility,stiffness degradation and energy dissipation capacity,and no obvious difference was observed between the seismic performance of the new walls and traditional walls.Comparisons were made between the experimental results and the calculated results of the shear capacity.It is concluded that the formulas in the two Chinese codes(GB 50011 and GB 50003) are suitable for the calculation of the shear capacity for the new types of walls,and the formula in GB 50011 tends to be more conservative.