期刊文献+
共找到1篇文章
< 1 >
每页显示 20 50 100
Short-term safety and efficacy of the biodegradable iron stent in mini-swine coronary arteries 被引量:7
1
作者 WU Chao QIU Hong +7 位作者 HU Xiao-ying RUAN Ying-mao TIAN Yi CHU Yan XU Xin-lin XU Liang TANG Yue GAO Run-lin 《Chinese Medical Journal》 SCIE CAS CSCD 2013年第24期4752-4757,共6页
Background To overcome the drawbacks of permanent years. The bioabsorbable polymer vascular scaffold (BVS) stents, biodegradable stents have been studied in recent was the first bioabsorbable stent to undergo clinic... Background To overcome the drawbacks of permanent years. The bioabsorbable polymer vascular scaffold (BVS) stents, biodegradable stents have been studied in recent was the first bioabsorbable stent to undergo clinical trials, demonstrating safety and feasibility in the ABSORB studies. Iron can potentially serve as the biomatedal for biodegradable stents. This study aimed to assess the short4erm safety and efficacy of a biodegradable iron stent in mini-swine coronary arteries. Methods Eight iron stents and eight cobalt chromium alloy (VISION) control stents were randomly implanted into the LAD and RCA of eight healthy mini-swine, respectively. Two stents of the same metal base were implanted into one animal. At 28 days the animals were sacrificed after coronary angiography, and histopathological examinations were performed. Results Histomorphometric measurements showed that mean neointimal thickness ((0.46±0.17) mm vs. (0.45±0.18) mm, P=0.878), neointimal area ((2.55±0.91) mm2 vs. (3.04±1.15) mm2, P=0.360) and percentage of area stenosis ((44.50±11.40)% vs. (46.00±17.95)%, P=0.845) were not significantly different between the iron stents and VISION stents. There was no inflammation, thrombosis or necrosis in either group. The scanning electron microscopy (SEM) intimal injury scores (0.75±1.04 vs. 0.88±0.99, P=0.809) and number of proliferating cell nuclear antigen (PCNA) positive staining cells were not significantly different between the two groups. The percentage of neointimal coverage by SEM examination was numerically higher in iron stents than in VISION stents ((84.38±14.50)% vs. (65.00±22.04)%, P=0.057), but the difference was not statistically significant. Iron staining in the tissue surrounding the iron stents at 28 days was positive and the vascular wall adjacent to the iron stent had a brownish tinge, consistent with iron degradation. No abnormal histopathological changes were detected in coronary arteries or major organs. Conclusions The biodegradable iron stent has good biocompatibility and short-term safety and efficacy in the mini- swine coronary artery. Corrosion of iron stents is observed at four weeks and no signs of organ toxicity related to iron degradation were noted. 展开更多
关键词 biodegradable iron stent mini-swine coronary artery histomorphometry
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部