Owing to the influence of sampling loss,cavity difference and detecting source,the multi-optical parameter measurement of atmospheric aerosol cannot be detected simultaneously in the same reference environment.In orde...Owing to the influence of sampling loss,cavity difference and detecting source,the multi-optical parameter measurement of atmospheric aerosol cannot be detected simultaneously in the same reference environment.In order to solve this problem,a new method of simultaneously detecting the aerosol optical parameters by coupling cavity ring-down spectrometer with photoacoustic spectroscopy is proposed.Firstly,the coupled photoacoustic cavity is formed by the organic fusion of the photoacoustic cavity and the ring-down cavity.Secondly,the integrated design of the coupling spectroscopy system is carried out.Finally,the extinction coefficient and absorption coefficient of aerosol are measured simultaneously by the system,and then the aerosol scattering coefficient and single albedo are calculated indirectly.The accuracy of the system is verified by comparing with the data from the environmental quality monitoring station,which provides a new idea for the detection of multi-optical characteristics of atmospheric aerosol.展开更多
基金supported by the Major Project of Natural Science Research in Universities of Anhui Province,China(Grant No.KJ2021ZD0052)the Open Foundation of Key Laboratory of Environmental Optics and Technology of Chinese Academy of Sciences(Grant No.2009DP1730652020-03)the Research and Development Project of Wuhu Research Institute of Anhui University of Science and Technology,China(Grant No.ALW2020YF17)。
文摘Owing to the influence of sampling loss,cavity difference and detecting source,the multi-optical parameter measurement of atmospheric aerosol cannot be detected simultaneously in the same reference environment.In order to solve this problem,a new method of simultaneously detecting the aerosol optical parameters by coupling cavity ring-down spectrometer with photoacoustic spectroscopy is proposed.Firstly,the coupled photoacoustic cavity is formed by the organic fusion of the photoacoustic cavity and the ring-down cavity.Secondly,the integrated design of the coupling spectroscopy system is carried out.Finally,the extinction coefficient and absorption coefficient of aerosol are measured simultaneously by the system,and then the aerosol scattering coefficient and single albedo are calculated indirectly.The accuracy of the system is verified by comparing with the data from the environmental quality monitoring station,which provides a new idea for the detection of multi-optical characteristics of atmospheric aerosol.
基金Projects(52174125, 51925402, 52004171) supported by the National Natural Science Foundation of ChinaProject(202103021222008) supported by the Outstanding Youth Cultivation Project in Shanxi Province,ChinaProject(SKLCR20-10) supported by the Open Fund of State Key Laboratory of Coal Resources in Western China。