Assessing Strategy of Power Transformers Insulation State Based on Part-division and Entropy Method 被引量:1
1
作者 LIAO Ruijin LIU Bin ZHANG Yiyi YANG Lijun ZHENG Hanbo 《高电压技术》 EI CAS CSCD 北大核心 2013年第8期1830-1836,共7页
Failure mechanisms of power transformers are complex and uncertain; it is difficult to determine index weights of insulation state. Therefore, it is a challenge to acquire an accurate assessment of insulation state of... Failure mechanisms of power transformers are complex and uncertain; it is difficult to determine index weights of insulation state. Therefore, it is a challenge to acquire an accurate assessment of insulation state of power transformers. In this paper, an assessing strategy for transformer insulation is proposed base on part-division of transformer and a comprehensive weight determination method. An index system of transformer is established on the basis of part-division of transformer. Each index’s weight is consisted of two parts, the constant weight and the variable weight, which are determined by improved analytic hierarchy process (AHP) and entropy method respectively. Af- ter categorizing insulation state into four levels and standardizing assessing indexes, a Cauchy membership function is forged, and a fuzzy algorithm is employed to simulate the uncertainty of the insulation state. Finally, a confidence criterion is employed to perform part-division based condition assessment of transformer. Case studies reveal that the proposed assessing strategy method is effective, convenient, and practical; with the new strategy, potential failures of transformers can be forecasted and insulation state of transformer parts can also be as- sessed. Furthermore, the assessing results can be used to guide condition-based maintenance. 展开更多
关键词 电力变压器 绝缘状态 评估策略 熵值法 国家战略 分划 改进层次分析法 指标权重
下载PDF
Short-Term Reliability Evaluation of Transmission System under Strong Wind and Rain
2
作者 Yanan Wei Qing Yang +2 位作者 Xiaofu Xiong Jian Wang Shijie Weng 《Journal of Power and Energy Engineering》 2014年第4期665-672,共8页
The impact of strong wind and rain loads will adversely affect the reliability of the overhead lines, it’s necessary to study changes in risk of transmission system and establish the reliability model of overhead lin... The impact of strong wind and rain loads will adversely affect the reliability of the overhead lines, it’s necessary to study changes in risk of transmission system and establish the reliability model of overhead lines through the strong wind and rain loads. In this article, the stochastic properties of overhead lines’ strength and loads were used, according to principles of structural reliability, time-dependent failure probability model of overhead lines was established under the impact of strong wind and rain loads. Simulation of the IEEE-79 system demonstrates that failure probability model is effective. This simulation result also shows that the impact of strong wind and rain loads will seriously affect reliability indices of system loads, rain loads cannot be ignored under strong wind and rain loads. 展开更多
关键词 STRONG WIND and RAIN Loads Transmission Line Structural RELIABILITY RELIABILITY Modeling
下载PDF
Modeling of Lightning Shielding Failure in UHV Transmission Line Based on Randomness Theory
3
作者 FU Jin YANG Qing +2 位作者 SIMA Wen-xia LI Jian-biao XIE Bo 《高电压技术》 EI CAS CSCD 北大核心 2008年第12期2542-2546,共5页
The operation data obtained abroad indicates that shielding failure in UHV transmission lines mostly accounts for the tripping-out accidents introduced by lightning striking the transmission line.Based on the discharg... The operation data obtained abroad indicates that shielding failure in UHV transmission lines mostly accounts for the tripping-out accidents introduced by lightning striking the transmission line.Based on the discharge theories of long air gap and randomness theory,a leader progression model of lightning shielding failure is presented in this paper.The random characteristics of the downward and upward leader are simulated in this model.The ground slope angel is also considered in this model by using coordinate transformation.Moreover,the system voltage is also taken into consideration in this model.The simulation results show that the good agreement between this model and the field data.And the results suggest that return striking exist obviously in UHV transmission line. 展开更多
关键词 UHV 随机理论 特高压输电线路 雷电屏蔽 模型
下载PDF
Short-Term Reliability Evaluation of Transmission System Using Lightning Strike Probability Prediction
4
作者 Jian Wang Qing Yang +1 位作者 Xiaofu Xiong Shijie Weng 《Journal of Power and Energy Engineering》 2014年第4期647-655,共9页
The transmission lines are exposed to the atmosphere nature and will be affected by adverse weather such as lightning storm, so that it will affect the reliability of transmission system. This paper studies the fault ... The transmission lines are exposed to the atmosphere nature and will be affected by adverse weather such as lightning storm, so that it will affect the reliability of transmission system. This paper studies the fault probability model of transmission line during the lightning storm, and evaluates the short-term reliability of transmission system in the forecasting weather condition. Firstly, build the lightning strike fault probability model of the transmission line based on historical lightning record information, then calculate the lightning strike probability under the forecasting weather conditions, furthermore evaluate the reliability index of transmission system. Utilizing IEEE RTS-79 system to verify the validity of the proposed model and the results show that lightning has great negative influence on the transmission lines and the reliability of transmission system. The reliability evaluation model proposed in this paper can guide the short-term operation and online scheduling for transmission system operators. 展开更多
关键词 LIGHTNING Transmission LINE Reliability Evaluation Information DIFFUSION
下载PDF
Assessment Method for the Reliability of Power Transformer Based on Fault-tree Analysis 被引量:15
5
作者 WANG You-yuan ZHOU Jing-jing CHEN Wei-gen DU Lin CHEN Ren-gang 《高电压技术》 EI CAS CSCD 北大核心 2009年第3期514-520,共7页
关键词 电力变压器 供电系统 故障树分析 失效模式
下载PDF
Numerical simulation and experimental validation of a direct current air corona discharge under atmospheric pressure 被引量:14
6
作者 刘兴华 何为 +3 位作者 杨帆 王虹宇 廖瑞金 肖汉光 《Chinese Physics B》 SCIE EI CAS CSCD 2012年第7期368-377,共10页
Air corona discharge is one of the critical problems associated with high-voltage equipment. Investigating the corona mechanism plays a key role in enhancing the electrical insulation performance. An improved self-con... Air corona discharge is one of the critical problems associated with high-voltage equipment. Investigating the corona mechanism plays a key role in enhancing the electrical insulation performance. An improved self-consistent multi-component two-dimensional plasma hybrid model is presented for the simulation of a direct current atmospheric pressure corona discharge in air. The model is based on plasma hydrodynamic and chemical models, and includes 12 species and 26 reactions. In addition, the photoionization effect is introduced into the model. The simulation on a bar-plate electrode configuration with an inter-electrode gap of 5.0 mm is carried out. The discharge voltage- current characteristics and the current density distribution predicted by the hybrid model agree with the experimental measurements. In addition, the dynamics of volume charged species generation, discharge current waveform, current density distribution at an electrode, charge density, electron temperature, and electric field variations are investigated in detail based on the model. The results indicate that the model can contribute valuable insights into the physics of an air plasma discharge. 展开更多
关键词 corona discharge hybrid model discharge voltage-current characteristics current den-sity distribution
下载PDF
Consensus problems of first-order dynamic multi-agent systems with multiple time delays 被引量:7
7
作者 纪良浩 廖晓峰 《Chinese Physics B》 SCIE EI CAS CSCD 2013年第4期50-55,共6页
Consensus problems of first-order multi-agent systems with multiple time delays are investigated in this paper. We discuss three cases: 1) continuous, 2) discrete, and 3) a continuous system with a proportional pl... Consensus problems of first-order multi-agent systems with multiple time delays are investigated in this paper. We discuss three cases: 1) continuous, 2) discrete, and 3) a continuous system with a proportional plus derivative controller. In each case, the system contains simultaneous communication and input time delays. Supposing a dynamic multi-agent system with directed topology that contains a globally reachable node, the sufficient convergence condition of the system is discussed with respect to each of the three cases based on the generalized Nyquist criterion and the frequency-domain analysis approach, yielding conclusions that are either less conservative than or agree with previously published results. We know that the convergence condition of the system depends mainly on each agent’s input time delay and the adjacent weights but is independent of the communication delay between agents, whether the system is continuous or discrete. Finally, simulation examples are given to verify the theoretical analysis. 展开更多
关键词 MULTI-AGENT time delays CONSENSUS FIRST-ORDER CONVERGENCE
下载PDF
Determination of Electron Swarm Parameters in Pure CHF_3 and CF_4 by a Time-Resolved Method 被引量:5
8
作者 肖登明 邓云坤 《Plasma Science and Technology》 SCIE EI CAS CSCD 2013年第1期25-29,共5页
The density-normalized effective ionization coefficient (α - η)/N (α and η are the ionization and attachment coefficients respectively), the electron drift velocity Ve and density- normalized longitudinal diff... The density-normalized effective ionization coefficient (α - η)/N (α and η are the ionization and attachment coefficients respectively), the electron drift velocity Ve and density- normalized longitudinal diffusion coefficient NDL in trifluoromethane (CHF3) and carbon tetraflu- oride (CF4) were measured using a pulsed Townsend technique over a wide E/N range. From the plots of (α- η)/N, we have derived the limiting field strength, (E/N)nm, which is valid for the analysis of insulation characteristics and applications to power equipment. Comparisons of the electron swarms parameters between CHF3 and CFa have been performed, and the global warming potential (GWP) is also taken into account. 展开更多
关键词 electron swarm parameters CHF3 CF4 pulse Townsend discharge GWP
下载PDF
Distance protection of EHV long transmission lines considering compensation degree of shunt reactor 被引量:7
9
作者 Wang Jiang Jiping Lu +2 位作者 Hongji Xiang Xing Ma Hui Fang 《Global Energy Interconnection》 2019年第1期64-70,共7页
This study investigated the feasibility of distance protection in extra-high voltage(EHV) networks. In long-distance transmission lines, the distributed parameter characteristic of the EHV network is obvious. When a f... This study investigated the feasibility of distance protection in extra-high voltage(EHV) networks. In long-distance transmission lines, the distributed parameter characteristic of the EHV network is obvious. When a fault occurs far away from the measurement site, the measured impedance might not be directly proportional to the fault distance, and the protection domain of distance protection will be decreased. The detailed theory inferred and proven in this paper reveals that this phenomenon is widespread in EHV transmission lines. The results indicate that the protection domain error is greatly reduced by the application of the shunt reactor. Overall, simulation results show that the proposed method is effective for impedance relay, considering different characteristics, different lengths of lines, and compensation degrees. 展开更多
关键词 EHV Distanee protection SHUNT REACTOR COMPENSATION DEGREE
下载PDF
Kinetics Characteristics and Bremsstrahlung of Argon DC Discharge Under Atmospheric Pressure 被引量:4
10
作者 何为 刘兴华 +4 位作者 咸日常 陈素红 廖瑞金 杨帆 肖汉光 《Plasma Science and Technology》 SCIE EI CAS CSCD 2013年第4期335-342,共8页
An improved self-consistent, multi-component, and one-dimensional plasma model for simulating atmospheric pressure argon glow discharge is presented. In the model, both the plasma hydrodynamics model and chemical mode... An improved self-consistent, multi-component, and one-dimensional plasma model for simulating atmospheric pressure argon glow discharge is presented. In the model, both the plasma hydrodynamics model and chemical model are considered. The numerical simulation is carried out for parallel-plate geometry with a separation of 0.06 cm. The results show that Ar* plays a major role in the discharge, which is mainly produced by ground state excitation reaction. The electron temperature reaches its maximum in the cathode sheath but maintains a low value (0.23 eV) in bulk plasma. Elastic collision is the dominant volumetric electron energy loss in atmosphere argon glow discharge, which is negligible in low pressure argon glow discharge. The metastable step-wise ionization is the main mechanism for electron production to sustain the discharge. However, the highest contribution to electron production rate is ground state ionization reaction. The bremsstrahlung power density is related to electric voltage. With the increase of the electric voltage, the bremsstrahlung power density increases, namely, the strength of ultraviolet radiation spectrum enhances in the cathode sheath. 展开更多
关键词 atmospheric pressure glow discharge plasma model metastable argon atom ionization reaction bremsstrahlung power density
下载PDF
Research on Propagation Characteristics of XLPE Cable Electrical Trees in different Electrode System 被引量:3
11
作者 ZHOU Quan YE Di +3 位作者 LIAO Rui-jin LIU Jia-bin REN Hai-jun CHEN Shi-jun 《高电压技术》 EI CAS CSCD 北大核心 2008年第12期2739-2744,共6页
The electrical tree discharge channel will be formed at concentrate spot of electric field in solid insulation dielectric,in order to study the difference of electrical tree under different electrical field,the short-... The electrical tree discharge channel will be formed at concentrate spot of electric field in solid insulation dielectric,in order to study the difference of electrical tree under different electrical field,the short-cable electrode system with actual XLPE cable was designed,experiments were performed under 12 kV,15 kV,18 kV,21 kV compare to the needle-plate electrode system.Experiment results show that the electrical tree of short-cable electrode system have the same growth trend with the needle-plate electrode system in the growing characteristic,the dense of electrical tree increase with the increase of voltage level,electrical tree of short-cable electrode system growth is slower than the needle-plate electrode system at the same voltage;To get the same shape of electrical tree,the voltage of short-cable electrode system must be higher than needle-plate electrode system,the results show that the semiconductor layer and the copper shield layer outside of XLPE cable have very important affection on the electrical trees degradation. 展开更多
关键词 电极系统 电树枝 生长特性 电缆 XLPE
下载PDF
Rough Set Theory Based Approach for Fault Diagnosis Rule Extraction of Distribution System 被引量:3
12
作者 ZHOU Yong-yong ZHOU Quan +4 位作者 LIU Jia-bin LIU Yu-ming REN Hai-jun SUN Cai-xin LIU Xu 《高电压技术》 EI CAS CSCD 北大核心 2008年第12期2713-2718,共6页
As the first step of service restoration of distribution system,rapid fault diagnosis is a significant task for reducing power outage time,decreasing outage loss,and subsequently improving service reliability and safe... As the first step of service restoration of distribution system,rapid fault diagnosis is a significant task for reducing power outage time,decreasing outage loss,and subsequently improving service reliability and safety.This paper analyzes a fault diagnosis approach by using rough set theory in which how to reduce decision table of data set is a main calculation intensive task.Aiming at this reduction problem,a heuristic reduction algorithm based on attribution length and frequency is proposed.At the same time,the corresponding value reduction method is proposed in order to fulfill the reduction and diagnosis rules extraction.Meanwhile,a Euclid matching method is introduced to solve confliction problems among the extracted rules when some information is lacking.Principal of the whole algorithm is clear and diagnostic rules distilled from the reduction are concise.Moreover,it needs less calculation towards specific discernibility matrix,and thus avoids the corresponding NP hard problem.The whole process is realized by MATLAB programming.A simulation example shows that the method has a fast calculation speed,and the extracted rules can reflect the characteristic of fault with a concise form.The rule database,formed by different reduction of decision table,can diagnose single fault and multi-faults efficiently,and give satisfied results even when the existed information is incomplete.The proposed method has good error-tolerate capability and the potential for on-line fault diagnosis. 展开更多
关键词 粗糙集理论 配电网 故障诊断 提取方法 规则匹配
下载PDF
Simulation Analysis on Lightning Accident of ± 500 kV DC Transmission Line Based on ATP-EMTP 被引量:3
13
作者 FU Jin SIMA Wen-xia +2 位作者 YANG Qing YANG Li-bin LI Zhi-tai 《高电压技术》 EI CAS CSCD 北大核心 2009年第4期802-808,共7页
关键词 高压电技术 闪电 意外事故 传输线
下载PDF
Three-dimensional Model Analysis of Electric Field Excited by Multi-circuit Intersecting Overhead Transmission Lines 被引量:2
14
作者 XIAO Dongping LEI Hui ZHANG Zhanlong HE Wei 《高电压技术》 EI CAS CSCD 北大核心 2013年第8期2006-2013,共8页
This work is carried out to predict the special distribution of electric field induced by multi-circuit intersecting overhead high-voltage (HV) transmission lines (TLs) within a large range without any expensive and t... This work is carried out to predict the special distribution of electric field induced by multi-circuit intersecting overhead high-voltage (HV) transmission lines (TLs) within a large range without any expensive and time-consuming computation. The two main parts of the presented methodology are 1) setting up a three-dimensional (3D) model to calculate the electric field based on combining ca- tenary equations with charge simulation method and 2) calculating the hybrid electric field excited by multi-circuit intersecting TLs using coordinate transformation and superposition technique. Examples of different TLs configurations, including a 220 kV single-circuit hori- zontally configured TLs, a 500 kV single-circuit triangularly configured TLs and a combination of the 220 kV TLs and the 550 kV TLs, are illustrated to verify the validity of this methodology. A more complicatal configurations, including a 500 kV double-circuit TLs and two 220 kV single-circuit horizontally configured TLs, are also calculated. Conclusions were drawn from the simulation: 1) The presented 3D model outperforms 2D models in describing the electric field distribution generated by practical HV TLs with sag and span. 2) Coordinate trans- formation and superposition technique considerably simplify the electric field computation for multi-circuit TLs configurations, which makes it possible to deal with complex engineering problems. 3) The electric field in the area covered by multiple intersecting overhead TLs is distorted and the hybrid electric field strength in some partial region increases so sharply that it might exceed the admissible value. 4) The configuration parameters of the TLs and the spatial configuration of multi-circuit TLs, for instance, the height of TLs, the length of span and the intersection angle of multiple circuits, influence the strength and the distribution of hybrid electric field. The influence regularities sum- marized in this paper can be referred by future TL designs to meet the electromagnetic environmental protection regulations. 展开更多
关键词 架空输电线路 电场分布 模型分析 相交 三维 多路 激发 220千伏
下载PDF
Combination Operation for Neutral Point of 35 kV Power Grids in Mountainous Area 被引量:2
15
作者 YUAN Tao SIMA Wen-xia +1 位作者 RAN Rui ZHU Wei 《高电压技术》 EI CAS CSCD 北大核心 2008年第12期2626-2630,共5页
Based on a lot of measurement and analysis,this paper find that the unbalanced nature of 35 kV grids due to unsymmetrical capacitance values gives difficulty in neutral point operation in mountainous area.Improving co... Based on a lot of measurement and analysis,this paper find that the unbalanced nature of 35 kV grids due to unsymmetrical capacitance values gives difficulty in neutral point operation in mountainous area.Improving compensation of Petersen coil can rectify imbalance of voltage but bring up new problem that Petersen coil can not extinguish grounding arc effectively in fault.To put down contradiction mentioned above,this paper proposes a combination operation for neutral point of 35 kV grids as neutral point insulated in routine operation and grounding through Petersen coil in fault,then EMTP simulation is carried out.Simulation indicates that new neutral operation method can improve lightning withstand level and decrease trip-out rate of grids. 展开更多
关键词 山区 补偿电网 消弧线圈 投切运行 暂态分析
下载PDF
Flashover Characteristics of Flat Plate Model Under DC Voltage in Wind-sand Condition 被引量:2
16
作者 SIMA Wen-xia MA Gao-quan YANG Qing 《高电压技术》 EI CAS CSCD 北大核心 2008年第12期2570-2574,共5页
The influence of sand dust on discharge of external insulation has caused widespread concern.At present,the research results show wind-sand electricity has a remarkable effect on the discharge characteristics of insul... The influence of sand dust on discharge of external insulation has caused widespread concern.At present,the research results show wind-sand electricity has a remarkable effect on the discharge characteristics of insulator and has little influence on the discharge characteristics of air gap.The flashover of insulator strings occurs along the insulator surface and air gaps,and the sand dust deposited on the insulator surface may affect the flashover characteristics of insulator strings.This paper studies the flashover characteristics of flat plate model under DC voltage in wind-sand condition.The experimental results show that under positive polarity voltage,the flashover voltage of the flat plate model has a maximum value,while under negative polarity voltage,the flashover voltage of the flat plate model has a minimum value with a certain degree of sand dust deposition.The wind or sand in sand-dust weather has an important effect on the flashover characteristics of the flat plate model.In certain variation range of electric charge,electric charge of sand dust has little effect on the flashover voltage of flat plate model under DC voltage.The deposition of sand has significant influence on the flashover process of flat plate model,which is related to the deposition density and moisture content of sand particle. 展开更多
关键词 风沙条件 平板模型 直流电 放电特性
下载PDF
Analysis of Conductors' Surface Electric Field of UHVDC Transmission Lines Based on Optimized Charge Simulation Method 被引量:2
17
作者 HU Qin SHU Li-chun +3 位作者 JIANG Xing-liang XUE Rong YUAN Qian fei ZHANG Shi-kun 《高电压技术》 EI CAS CSCD 北大核心 2008年第12期2547-2551,共5页
The choice of the UHV lines depends on surface electric field of the bundle conductors.Based on existing calculation methods,the optimized charge simulation method is used to calculate the conductors' surface elec... The choice of the UHV lines depends on surface electric field of the bundle conductors.Based on existing calculation methods,the optimized charge simulation method is used to calculate the conductors' surface electrical field of±800 kV UHVDC transmission lines in this paper.During calculation,the offset distance is set as the variance of the objective function,the position and the quantity of the simulation charges are optimized with the gold section method,and the surface electrical field is calculated when the charge is in the optimal position.The result shows that the distribution of the surface electrical field and its maximal value can be calculated accurately with this method,although less number of simulation charges is used in this proposed method and the calculation is simple. 展开更多
关键词 UHVDC 模拟电荷法 特高压直流导线 电场
下载PDF
Study on Power Transformers Fault Diagnosis Based on Wavelet Neural Network and D-S Evidence Theory
18
作者 LIANG Liu-ming CHEN Wei-gen +2 位作者 YUE Yan-feng WEI Chao YANG Jian-feng 《高电压技术》 EI CAS CSCD 北大核心 2008年第12期2694-2700,共7页
>Transformer faults are quite complicated phenomena and can occur due to a variety of reasons.There have been several methods for transformer fault synthetic diagnosis,but each of them has its own limitations in re... >Transformer faults are quite complicated phenomena and can occur due to a variety of reasons.There have been several methods for transformer fault synthetic diagnosis,but each of them has its own limitations in real fault diagnosis applications.In order to overcome those shortcomings in the existing methods,a new transformer fault diagnosis method based on a wavelet neural network optimized by adaptive genetic algorithm(AGA)and an improved D-S evidence theory fusion technique is proposed in this paper.The proposed method combines the oil chromatogram data and the off-line electrical test data of transformers to carry out fault diagnosis.Based on the fusion mechanism of D-S evidence theory,the comprehensive reliability of evidence is constructed by considering the evidence importance,the outputs of the neural network and the expert experience.The new method increases the objectivity of the basic probability assignment(BPA)and reduces the basic probability assigned for uncertain and unimportant information.The case study results of using the proposed method show that it has a good performance of fault diagnosis for transformers. 展开更多
关键词 小波神经网络 D-S证据理论 电力变压器 故障诊断 适应基因算法
下载PDF
Fuzzy Risk Assessment Model of Power Transformer Based on Borda Number Theory
19
作者 WANG You-yuan YUAN Yuan LI Jian DU Lin ZHOU Jing-jing 《高电压技术》 EI CAS CSCD 北大核心 2008年第12期2668-2673,共6页
The power transformer is the key equipment of transforming voltage and exchanging power in the power system.It's safe and reliable operation directly influences the safe level of the power system.To study the risk... The power transformer is the key equipment of transforming voltage and exchanging power in the power system.It's safe and reliable operation directly influences the safe level of the power system.To study the risk assessment of power transformer which is very significant to improve the reliability of the power system,a fuzzy comprehensive risk assessment model of power transformer based on Borda number theory is proposed in this paper.At first,the fault types and risk factors of the power transformer are analyzed.Secondly,the basic framework of the fuzzy comprehensive evaluation is applied to quantify the risk factors.And then,Borda number theory is employed to analyze influence degree and occurrence probability of power transformer.At last,the various risk factors impact index and fuzzy comprehensive evaluation index of power transformer can be easily obtained.Applying this model,the relative importance degree of the risk factors can be horizontally compared according to the numerical index,the engineering staff can directly get the parameters of the transformer risk level and get a good description of the visual expression through using 5 score and similar visual language. 展开更多
关键词 模糊风险评估模型 Borda数理论 电力变压器 故障树结构
下载PDF
Frequency-locking and threshold current-lowering effects of a quantum cascade laser and an application in gas detection field
20
作者 陈伟根 万福 +2 位作者 邹经鑫 顾朝亮 周渠 《Chinese Physics B》 SCIE EI CAS CSCD 2015年第2期165-169,共5页
In this paper,the frequency-locking and threshold current-lowering effects of a quantum cascade laser are studied and achieved.Combined with cavity-enhanced absorption spectroscopy,the noninvasive detection of H_2 wit... In this paper,the frequency-locking and threshold current-lowering effects of a quantum cascade laser are studied and achieved.Combined with cavity-enhanced absorption spectroscopy,the noninvasive detection of H_2 with a prepared concentration of 500 ppm in multiple dissolved gases is performed and evaluated.The high frequency selectivity of 0.0051 cm^-1 at an acquisition time of 1 s allows the sensitive detection of the(1-0) S(l) band of H_2 with a high accuracy of(96.53±0.29)%and shows that the detection limit to an absorption line of 4712.9046 cm^-1 is approximately(17.26±0.63) ppm at an atmospheric pressure and a temperature of 20 ℃. 展开更多
关键词 quantum cascade laser frequency locking threshold current lowering cavity-enhanced absorptionspectroscopy
下载PDF