Objective To detect Japanese encephalitis virus(JEV) rapidly and distinguish its genotypes, a TaqMan-based reverse transcriptase quantitative polymerase chain reaction(RT-PCR) detection system was developed.Method...Objective To detect Japanese encephalitis virus(JEV) rapidly and distinguish its genotypes, a TaqMan-based reverse transcriptase quantitative polymerase chain reaction(RT-PCR) detection system was developed.Methods By aligning the full-length sequences of JEV(G1-G5), six sets of highly specific TaqMan real-time RT-PCR primers and probes were designed based on the highly conserved NS1, NS2, and M genes of JEV, which included one set for non-specific JEV detection and five sets for the detection of specific JEV genotypes. Twenty batches of mosquito samples were used to evaluate our quantitative PCR assay.Results With the specific assay, no other flavivirus were detected. The lower limits of detection of the system were 1 pfu/mL for JEV titers and 100 RNA copies/μL. The coefficients of variation of this real-time RT-PCR were all 〈 2.8%. The amplification efficiency of this method was between 90% and 103%.Conclusion A TaqMan real-time RT-PCR detection system was successfully established to detect and differentiate all five JEV genotypes.展开更多
基金supported by grants from the National Key Research and Development Program[2016YFD0500401]Development Grant of State Key Laboratory of Infectious Disease Prevention and Control[2015SKLID505,2014SKLID03]
文摘Objective To detect Japanese encephalitis virus(JEV) rapidly and distinguish its genotypes, a TaqMan-based reverse transcriptase quantitative polymerase chain reaction(RT-PCR) detection system was developed.Methods By aligning the full-length sequences of JEV(G1-G5), six sets of highly specific TaqMan real-time RT-PCR primers and probes were designed based on the highly conserved NS1, NS2, and M genes of JEV, which included one set for non-specific JEV detection and five sets for the detection of specific JEV genotypes. Twenty batches of mosquito samples were used to evaluate our quantitative PCR assay.Results With the specific assay, no other flavivirus were detected. The lower limits of detection of the system were 1 pfu/mL for JEV titers and 100 RNA copies/μL. The coefficients of variation of this real-time RT-PCR were all 〈 2.8%. The amplification efficiency of this method was between 90% and 103%.Conclusion A TaqMan real-time RT-PCR detection system was successfully established to detect and differentiate all five JEV genotypes.