期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
An Experimental Study on the Behavior of Shear Keys According to the Curing Time of UHPC 被引量:7
1
作者 Hee Seok Kim Won Jong Chin +2 位作者 Jeong Rae Cho Young Jin Kim Hyejin Yoon 《Engineering(科研)》 2015年第4期212-218,共7页
Precast segmental construction has been recently developed to reduce the construction cost and shorten the construction term as compared to the cast-in-place method in a will to establish the design and erection syste... Precast segmental construction has been recently developed to reduce the construction cost and shorten the construction term as compared to the cast-in-place method in a will to establish the design and erection system of structures using Ultra High Performance Concrete (UHPC). However, this method requires the presence of segmental joints to transfer the loads between neighboring segments, which stresses the importance of securing structural safety and serviceability. Therefore, need is for research on the behavior of the segmental joint for the structures erected by the precast segmental construction method. To that goal, this paper presents an experimental study on the behavior of shear keys with respect to the curing time of UHPC in the segmental joint. Analysis is done on the load-displacement relation according to the curing time of the shear keys and on the failure modes of the shear keys according to the cracking pattern at failure. 展开更多
关键词 Ultra High Performance Concrete PRECAST SEGMENTAL Joint CURING Time SHEAR KEY
下载PDF
Connection between Concrete Layers with Different Strengths 被引量:1
2
作者 Jae Yoon Kang Jong Sup Park +1 位作者 Woo Tai Jung Moon Seoung Keum 《Engineering(科研)》 2015年第7期365-372,共8页
As part of a research intending to develop steel-concrete hybrid girder using ultra high performance concrete with compressive strength of 80 MPa, this study conducts loading test on this girder to investigate the met... As part of a research intending to develop steel-concrete hybrid girder using ultra high performance concrete with compressive strength of 80 MPa, this study conducts loading test on this girder to investigate the methods for its composition with a slab using 30 MPa-concrete and the corresponding interfacial behavior. Prior to the loading test, the design formula of the Eurocode for the shear resistance developed in concrete-to-concrete interface is examined for the interface between concrete layers of different strengths. The effect of the surface roughness on the shear resistance is examined using this formula and finite element analysis to verify the applicability of the formula. Based upon the results, loading test is conducted on girder specimens to evaluate the actual behavior with respect to the interfacial surface condition. The test results reveal that the specimen with rough interface could not develop perfectly composite behavior and experienced adhesive failure. In case of simultaneous action of flexure and shear, it appears that conservative design should be applied without consideration of the interfacial condition when determining the arrangement of shear reinforcement. 展开更多
关键词 Shear Resistance Interface BETWEEN CONCRETE LAYERS Surface ROUGHNESS STEEL-CONCRETE Hybrid GIRDER Ultra High Performance CONCRETE (UHPC)
下载PDF
Numerical Analysis of a Gravity Substructure for 5 MW Offshore Wind Turbines Due to Soil Conditions
3
作者 Min-Su Park Youn-Ju Jeong Young-Jun You 《Journal of Energy and Power Engineering》 2016年第3期150-158,共9页
关键词 风力发电机组 子结构 重力 数值分析 土-结构相互作用 风力涡轮机 ANSYS 近海
下载PDF
Shear Behavior in Indented Concrete Layers with Different Strengths
4
作者 Jae-Yoon Kang Jong-Sup Park +1 位作者 Woo-Tai Jung Moon-Seoung Keum 《Engineering(科研)》 2016年第7期423-431,共9页
This paper investigates the design formula for the shear strength at the concrete-to-concrete interface proposed in Eurocode with regard to concrete layers with different strengths. Based upon the results of the study... This paper investigates the design formula for the shear strength at the concrete-to-concrete interface proposed in Eurocode with regard to concrete layers with different strengths. Based upon the results of the study on the applicability of the design formula, push-off test is conducted on specimens with various indented interfaces to evaluate the actual behavior with respect to the surface roughness. The experimental results reveal that the interfacial shear strength increases with higher compressive strength of the concrete layers presenting different strengths and that the shear strength at the indented interface differs by 20% to 50% compared to the value predicted by the design formula. Especially, the shear strength developed between the concrete layers with different strengths appears to be different from the prediction of the design formula as much as the layers present larger difference in their compressive strengths. 展开更多
关键词 Shear Strength Interface of Concrete Layers Surface Roughness Indented Surface Push-Off Test
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部