Problems in metal-on-metal (MoM) hip replacement systems still persist due to high wear rates, low corrosion resistance and release of toxic ions and nanoparticles. As a consequence of these effects, failure, infectio...Problems in metal-on-metal (MoM) hip replacement systems still persist due to high wear rates, low corrosion resistance and release of toxic ions and nanoparticles. As a consequence of these effects, failure, infections, loosening or bone resorption is the typical problems in the hip prosthesis. In order to reduce failure due to corrosion and/or releasing ions and particles, this study presents some works in a novel nanoscale surface modification of cobalt-chromium alloy (CoCr) for obtaining improved surface conditions in these alloys for these applications. Improving corrosion resistant of these alloys and achieving a low wear rate are possible to reduce the total released ions and particles released from the surface of this material. According to it, three different treatments using oxygen at temperatures of 300°C, 350°C and 400°C were carried out by plasma immersion ion implantation technique (PI3). X-ray diffraction (XRD) analysis shows an increase in the formation of chromium oxides in the outer surface of the CoCr alloy. It allows improving in corrosion resistant in CoCr alloys. Moreover, total quantity of released Co, Cr and Mo ions have been reduced. Wear rate studies showed a very similar behaviour after the treatments in relation to untreated CoCr alloy and release rate from the treated surface of CoCr alloys was reduced in comparison with untreated CoCr alloy.展开更多
Fe-based powder with a composition of Fe_(42.87)Cr_(15.98)Mo_(16.33)C_(15.94)B_(8.88)(at.%)was used to fabricate coatings by high-velocity oxygen fuel spraying.The effects of the spraying parameters on the...Fe-based powder with a composition of Fe_(42.87)Cr_(15.98)Mo_(16.33)C_(15.94)B_(8.88)(at.%)was used to fabricate coatings by high-velocity oxygen fuel spraying.The effects of the spraying parameters on the microstructure and the wear properties of the Fe-based alloy coatings were systematically studied.The results showed that the obtained Fe-based coatings with a thickness of about 400μm consisted of a large-volume amorphous phase and some nanocrystals.With increasing the fuel and oxygen flow rates,the porosity of the obtained coatings decreased.The coating deposited under optimized parameters exhibited the lowest porosity of 2.8%.The excellent wear resistance of this coating was attributed to the properties of the amorphous matrix and the presence of nanocrystals homogeneously distributed within the matrix.The wear mechanism of the coatings was discussed on the basis of observations of the worn surfaces.展开更多
基金the Ministry of Science and Innovacion&Navarra Government for FUNCOAT projectthe Ministry of Economy and Competitiveness for MoM for LIFE(MAT2011-29698-C03-02)and for providing financial support to these projects.
文摘Problems in metal-on-metal (MoM) hip replacement systems still persist due to high wear rates, low corrosion resistance and release of toxic ions and nanoparticles. As a consequence of these effects, failure, infections, loosening or bone resorption is the typical problems in the hip prosthesis. In order to reduce failure due to corrosion and/or releasing ions and particles, this study presents some works in a novel nanoscale surface modification of cobalt-chromium alloy (CoCr) for obtaining improved surface conditions in these alloys for these applications. Improving corrosion resistant of these alloys and achieving a low wear rate are possible to reduce the total released ions and particles released from the surface of this material. According to it, three different treatments using oxygen at temperatures of 300°C, 350°C and 400°C were carried out by plasma immersion ion implantation technique (PI3). X-ray diffraction (XRD) analysis shows an increase in the formation of chromium oxides in the outer surface of the CoCr alloy. It allows improving in corrosion resistant in CoCr alloys. Moreover, total quantity of released Co, Cr and Mo ions have been reduced. Wear rate studies showed a very similar behaviour after the treatments in relation to untreated CoCr alloy and release rate from the treated surface of CoCr alloys was reduced in comparison with untreated CoCr alloy.
基金Item Sponsored by National Natural Science Foundation of China(51205001)Key Project of Natural Science of Education Department of Anhui Province of China(KJ2014A023)Scientific Research Starting Foundation of Anhui Polytechnic University of China(2012YQQ006)
文摘Fe-based powder with a composition of Fe_(42.87)Cr_(15.98)Mo_(16.33)C_(15.94)B_(8.88)(at.%)was used to fabricate coatings by high-velocity oxygen fuel spraying.The effects of the spraying parameters on the microstructure and the wear properties of the Fe-based alloy coatings were systematically studied.The results showed that the obtained Fe-based coatings with a thickness of about 400μm consisted of a large-volume amorphous phase and some nanocrystals.With increasing the fuel and oxygen flow rates,the porosity of the obtained coatings decreased.The coating deposited under optimized parameters exhibited the lowest porosity of 2.8%.The excellent wear resistance of this coating was attributed to the properties of the amorphous matrix and the presence of nanocrystals homogeneously distributed within the matrix.The wear mechanism of the coatings was discussed on the basis of observations of the worn surfaces.