期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
The present status of the Shanghai electron beam ion trap
1
作者 GUO Pan-Lin HU Wei +11 位作者 GONG Pei-Rong LU Di HE Mian-Hong WU Shimin YAO Ke HUANG Min ZHANG Xue-Mei WANG Xin-Cheng ZHU Xi-Kai JIANG Di-Kui HUTTON R ZOU Ya-Ming 《Nuclear Science and Techniques》 SCIE CAS CSCD 2005年第6期335-337,共3页
In this report, an introduction to the structure of Shanghai EBIT, a brief description of the status ofShanghai EBIT project, and a short discussion of the first results of Shanghai EBIT are presented.
关键词 上海 电子束 原子物理学 电离
下载PDF
Resonance Excitation Rate Coefficient of Ni-Like Tantalum
2
作者 沈天明 陈重阳 +1 位作者 王炎森 顾明峰 《Chinese Physics Letters》 SCIE CAS CSCD 2007年第4期925-928,共4页
The ab initio calculations of electron-impact resonant excitation rate coefficients from the ground level to 54 fine-structure levels of 3d94l (1 = s, p, d, f) configurations of Ni-like tantalum ion are performed by... The ab initio calculations of electron-impact resonant excitation rate coefficients from the ground level to 54 fine-structure levels of 3d94l (1 = s, p, d, f) configurations of Ni-like tantalum ion are performed by using a fully relativistic distorted-wave approximation. The configuration-interaction effects are taken into account. The decays to autoionizing levels possibly followed by autoionization cascades are also included in the calculation. The contributions from doubly-excited intermediate states of Cu-like 31^17n′l′n′l″ (n′ = 4, 5; n″ = 5 - 15) are calculated explicitly, and the contributions from high Rydberg states (n″〉 15) are taken into account by using n-3 scaling law. The present results should be more accurate than the existent calculations. 展开更多
关键词 RECOMBINATION RATE COEFFICIENTS DIELECTRONIC RECOMBINATION COLLISIONSTRENGTHS IONS CONFIGURATIONS ISOSEQUENCES FE CA MG AR
下载PDF
A multi-parameter data acquisition system for the collision research platform at Shanghai EBIT
3
作者 WANG Xincheng WEI Baoren +4 位作者 YANG Yang SHEN Yang XIAO Jun ZHANG Xuemei ZOU Yarning 《Nuclear Science and Techniques》 SCIE CAS CSCD 2009年第1期51-55,共5页
In this work we describe a multi-parameter data acquisition system(DAQ)which has been developed for the Shanghai EBIT.This system is operated at the collision research platform which includes a recoil-ion momentum spe... In this work we describe a multi-parameter data acquisition system(DAQ)which has been developed for the Shanghai EBIT.This system is operated at the collision research platform which includes a recoil-ion momentum spectrometer(RIMS).We have employed DAQ based on the VME system,which is a very fast developing system within the RIMS community,and with which we can reach data transfer rates of up to 160 Mb·s- 1.The software developed for DAQ based on UnisDX-XP is also described. 展开更多
关键词 VME TDC ADC 数据采集系统
下载PDF
Effects of Configuration Interaction on Dielectronic Recombination of Cu-Like Gold Ion through 3d + e→4l′4l″ Capture Process
4
作者 孟凡昌 陈重阳 +1 位作者 王炎森 邹亚明 《Chinese Physics Letters》 SCIE CAS CSCD 2007年第12期3404-3407,共4页
Effects of configuration interaction on dielectronic recombination of Cu-fike gold ions through the 3d + e→4l′4l″ capture process are studied in the models of isolated configurations approximation, configuration m... Effects of configuration interaction on dielectronic recombination of Cu-fike gold ions through the 3d + e→4l′4l″ capture process are studied in the models of isolated configurations approximation, configuration mixing within 3d^94s4l′4″, and configuration mixing within 3d^94l4l′4l″ (l≥ 0), employing a relativistic distorted-wave approximation. Nonresonant raditive stabilizing transitions and decays to autoionizing levels followed by radiative cascades, as well as resonant stabilizing transitions from the resonant levels, are taken into account. The additional mixing with 3d^94l4l′4l″ (0 〈 l 〈 l′ 〈l″≤ 3) shifts slightly the peaks of cross section towards low energy. The rate coefficient at low temperature is dramatically changed. The rate coefficient at temperature above 100 eV is enhanced by a factor between 26% and 13%. 展开更多
下载PDF
A K-CELL injection system for SH-PermEBIT
5
作者 韩川 赵瑞峰 +2 位作者 施展 Roger Hutton 路迪 《Nuclear Science and Techniques》 SCIE CAS CSCD 2014年第4期21-23,共3页
In this paper,we report a newly developed Knudsen Cell injection system for SH-PermEBIT.This technique can overcome disadvantages of introducing organometallic gases and wired probes into EBIT and provide steady conti... In this paper,we report a newly developed Knudsen Cell injection system for SH-PermEBIT.This technique can overcome disadvantages of introducing organometallic gases and wired probes into EBIT and provide steady continuous injection.A specially designed vacuum line is used to ensure that the Knudsen Cell satisfies the vacuum level of SH-permEBIT.Using this system we successfully injected ytterbium into the SH-permEBIT and recorded a spectrum in the visible wavelength region. 展开更多
关键词 喷射系统 注射系统 EBIT 有机气体 波长范围 真空度 可见光 细胞
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部