The choked back pressure characteristic of the steam turbine unit with air cooled condenser is very different with the unit with wet cooling technology, and the understanding of the choked back pressure performance ch...The choked back pressure characteristic of the steam turbine unit with air cooled condenser is very different with the unit with wet cooling technology, and the understanding of the choked back pressure performance change with operation load is important to guide the economic operation of the unit. One simplified Variable Operation Condition Analysis Method was put forward for calculation of the unit output-turbine back pressure characteristics. Based on this method, the choked back pressure for each operation load can be determined. An example was given for a super-critical, regenerative single-shaft, 2-casing with 2-exhaust steam turbine generation unit with air cooled condenser. The calculation result was provided and compared with the result of the unit with wet cooling technology.展开更多
To analyze the unit performance degradation for top heater out-of-service operation condition, two calculation methods were introduced, that was the model based calculation method and the simplified variable operation...To analyze the unit performance degradation for top heater out-of-service operation condition, two calculation methods were introduced, that was the model based calculation method and the simplified variable operation condition analysis method. A 600MW sub-critical steam turbine unit with air cooled condenser was analyzed using the two introduced methods. It is shown that calculation data got can reflect the redistribution effect on steam flows of the turbine extractions and turbine internals due to the top heater out-of-service, and similar and close calculation results were got from the two methods, and both results were lower than result calculated using the commonly used equivalent enthalpy drop method.展开更多
文摘The choked back pressure characteristic of the steam turbine unit with air cooled condenser is very different with the unit with wet cooling technology, and the understanding of the choked back pressure performance change with operation load is important to guide the economic operation of the unit. One simplified Variable Operation Condition Analysis Method was put forward for calculation of the unit output-turbine back pressure characteristics. Based on this method, the choked back pressure for each operation load can be determined. An example was given for a super-critical, regenerative single-shaft, 2-casing with 2-exhaust steam turbine generation unit with air cooled condenser. The calculation result was provided and compared with the result of the unit with wet cooling technology.
文摘To analyze the unit performance degradation for top heater out-of-service operation condition, two calculation methods were introduced, that was the model based calculation method and the simplified variable operation condition analysis method. A 600MW sub-critical steam turbine unit with air cooled condenser was analyzed using the two introduced methods. It is shown that calculation data got can reflect the redistribution effect on steam flows of the turbine extractions and turbine internals due to the top heater out-of-service, and similar and close calculation results were got from the two methods, and both results were lower than result calculated using the commonly used equivalent enthalpy drop method.