期刊文献+
共找到1篇文章
< 1 >
每页显示 20 50 100
On the Perturbation Correction Factor <i>p<sub>cav</sub></i>of the Markus Parallel-Plate Ion Chamber in Clinical Electron Beams
1
作者 Philip von Voigts-Rhetz Hilke Vorwerk Klemens Zink 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2017年第2期150-161,共12页
Purpose: All present dosimetry protocols recommend well-guarded parallelplate ion chambers for electron dosimetry. For the guard-less Markus chamber, an energy dependent fluence perturbation correction pcav is given. ... Purpose: All present dosimetry protocols recommend well-guarded parallelplate ion chambers for electron dosimetry. For the guard-less Markus chamber, an energy dependent fluence perturbation correction pcav is given. This perturbation correction was experimentally determined by van der Plaetsen by comparison of the read-out of a Markus and a NACP chamber, which was assumed to be “perturbation-free”. Aim of the present study is a Monte Carlo based reiteration of this experiment. Methods: Detailed models of four parallel-plate chambers (Roos, Markus, NACP and Advanced Markus) were designed using the Monte Carlo code EGSnrc and placed in a water phantom. For all chambers, the dose to the active volume filled with low density water was calculated for 13 clinical electron spectra (E0 = 6 - 21 MeV) and three energies of an Electra linear accelerator at the depth of maximum and at the reference depth under reference conditions. In all cases, the chamber’s reference point was positioned at the depth of measurement. Moreover, the dose to water DW was calculated in a small water voxel positioned at the same depth. Results: The calculated dose ratio DNACP/DMarkus, which according to van der Plaetsen reflects the fluence perturbation correction of the Markus chamber, deviates less from unity than the values given by van der Plaetsen, but exhibits similar energy dependence. The same holds for the dose ratios of the other well-guarded chambers. But, in comparison to water, the Markus chamber reveals the smallest overall perturbation correction which is nearly energy independent at both investigated depths. Conclusion: The simulations principally confirm the energy dependence of the dose ratio DNACP/DMarkus as published by van der Plaetsen. But, as shown by our simulations of the ratio DW/DMarkus, the conclusion drawn in all dosimetry protocols is questionable: in contrast to all well-guarded chambers, the guard-less Markus chamber reveals the smallest overall perturbation correction and also the smallest energy dependence. 展开更多
关键词 EGSNRC Monte Carlo Cavity PERTURBATION Ionization CHAMBER
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部