The reliability analysis of vertically integrated protection devices is crucial for designing International Electrotechnical Commission(IEC)61850-based substations.This paper presents the hardware architecture of a fo...The reliability analysis of vertically integrated protection devices is crucial for designing International Electrotechnical Commission(IEC)61850-based substations.This paper presents the hardware architecture of a four-inone vertically integrated device and the information transmission path of each function based on the functional information transmission chain of protection devices,measurement and control devices,merging units,and intelligent terminals.Additionally,a reliability analysis model of the protection device and its protection system is constructed using the fault tree analysis method while considering the characteristics of each module of the vertically integrated device.The stability probability of the protection system in each state is analyzed by combining the state-transfer equations of line and busbar protection with a Markov chain.Finally,the failure rate and availability of the protection device and its protection system are calculated under different ambient temperatures using a 110 kV intelligent substation as an example.The sensitivity of each device module is analyzed.展开更多
In this paper, we propose a novel anomaly detection method for data centers based on a combination of graphstructure and abnormal attention mechanism. The method leverages the sensor monitoring data from targetpower s...In this paper, we propose a novel anomaly detection method for data centers based on a combination of graphstructure and abnormal attention mechanism. The method leverages the sensor monitoring data from targetpower substations to construct multidimensional time series. These time series are subsequently transformed intograph structures, and corresponding adjacency matrices are obtained. By incorporating the adjacency matricesand additional weights associated with the graph structure, an aggregation matrix is derived. The aggregationmatrix is then fed into a pre-trained graph convolutional neural network (GCN) to extract graph structure features.Moreover, both themultidimensional time series segments and the graph structure features are inputted into a pretrainedanomaly detectionmodel, resulting in corresponding anomaly detection results that help identify abnormaldata. The anomaly detection model consists of a multi-level encoder-decoder module, wherein each level includesa transformer encoder and decoder based on correlation differences. The attention module in the encoding layeradopts an abnormal attention module with a dual-branch structure. Experimental results demonstrate that ourproposed method significantly improves the accuracy and stability of anomaly detection.展开更多
As extreme weather events have become more frequent in recent years,improving the resilience and reliability of power systems has become an important area of concern.In this paper,a robust preventive-corrective securi...As extreme weather events have become more frequent in recent years,improving the resilience and reliability of power systems has become an important area of concern.In this paper,a robust preventive-corrective security-constrained optimal power flow(RO-PCSCOPF)model is proposed to improve power system reliability under N−k outages.Both the short-term emergency limit(STL)and the long-term operating limit(LTL)of the post-contingency power flow on the branch are considered.Compared with the existing robust corrective SCOPF model that only considers STL or LTL,the proposed ROPCSCOPF model can achieve a more reliable generation dispatch solution.In addition,this paper also summarizes and compares the solution methods for solving the N−k SCOPF problem.The computational efficiency of the classical Benders decomposition(BD)method,robust optimization(RO)method,and line outage distribution factor(LODF)method are investigated on the IEEE 24-bus Reliability Test System and 118-bus system.Simulation results show that the BD method has the worst computation performance.The RO method and the LODF method have comparable performance.However,the LODF method can only be used for the preventive SCOPF and not for the corrective SCOPF.The RO method can be used for both.展开更多
基金supported by the 2020 Infrastructure Engineering Technology Innovation Projectthe“Intelligent Substation”Supporting Technology Research Project(031200WS22200001)。
文摘The reliability analysis of vertically integrated protection devices is crucial for designing International Electrotechnical Commission(IEC)61850-based substations.This paper presents the hardware architecture of a four-inone vertically integrated device and the information transmission path of each function based on the functional information transmission chain of protection devices,measurement and control devices,merging units,and intelligent terminals.Additionally,a reliability analysis model of the protection device and its protection system is constructed using the fault tree analysis method while considering the characteristics of each module of the vertically integrated device.The stability probability of the protection system in each state is analyzed by combining the state-transfer equations of line and busbar protection with a Markov chain.Finally,the failure rate and availability of the protection device and its protection system are calculated under different ambient temperatures using a 110 kV intelligent substation as an example.The sensitivity of each device module is analyzed.
基金the Science and Technology Project of China Southern Power Grid Company,Ltd.(031200KK52200003)the National Natural Science Foundation of China(Nos.62371253,52278119).
文摘In this paper, we propose a novel anomaly detection method for data centers based on a combination of graphstructure and abnormal attention mechanism. The method leverages the sensor monitoring data from targetpower substations to construct multidimensional time series. These time series are subsequently transformed intograph structures, and corresponding adjacency matrices are obtained. By incorporating the adjacency matricesand additional weights associated with the graph structure, an aggregation matrix is derived. The aggregationmatrix is then fed into a pre-trained graph convolutional neural network (GCN) to extract graph structure features.Moreover, both themultidimensional time series segments and the graph structure features are inputted into a pretrainedanomaly detectionmodel, resulting in corresponding anomaly detection results that help identify abnormaldata. The anomaly detection model consists of a multi-level encoder-decoder module, wherein each level includesa transformer encoder and decoder based on correlation differences. The attention module in the encoding layeradopts an abnormal attention module with a dual-branch structure. Experimental results demonstrate that ourproposed method significantly improves the accuracy and stability of anomaly detection.
基金This work was supported by the Education Department of Guangdong Province:New and Integrated Energy System Theory and Technology Research Group(No.2016KCXTD022)National Natural Science Foundation of China(No.51907031)+2 种基金Guangdong Basic and Applied Basic Research Foundation(Guangdong-Guangxi Joint Foundation)(No.2021A1515410009)China Scholarship CouncilBrunel University London BRIEF Funding。
文摘As extreme weather events have become more frequent in recent years,improving the resilience and reliability of power systems has become an important area of concern.In this paper,a robust preventive-corrective security-constrained optimal power flow(RO-PCSCOPF)model is proposed to improve power system reliability under N−k outages.Both the short-term emergency limit(STL)and the long-term operating limit(LTL)of the post-contingency power flow on the branch are considered.Compared with the existing robust corrective SCOPF model that only considers STL or LTL,the proposed ROPCSCOPF model can achieve a more reliable generation dispatch solution.In addition,this paper also summarizes and compares the solution methods for solving the N−k SCOPF problem.The computational efficiency of the classical Benders decomposition(BD)method,robust optimization(RO)method,and line outage distribution factor(LODF)method are investigated on the IEEE 24-bus Reliability Test System and 118-bus system.Simulation results show that the BD method has the worst computation performance.The RO method and the LODF method have comparable performance.However,the LODF method can only be used for the preventive SCOPF and not for the corrective SCOPF.The RO method can be used for both.