Objective: The aim of this study was to improve muscle flaps and to evaluate surgical outcomes with the use of a novel specialized retractor, which is a surgical instrument used to locate and shape a bony seat for min...Objective: The aim of this study was to improve muscle flaps and to evaluate surgical outcomes with the use of a novel specialized retractor, which is a surgical instrument used to locate and shape a bony seat for minimally invasive cochlear implantation.Methods: 50 patients aged 1 e75 years with sensorineural hearing loss who required cochlear implantation were recruited. A small incision(<3 cm) was made, and the novel specialized retractor was used in the study group during cochlear implantation. The incision length, surgical outcomes and operative time were recorded and analyzed.Results: The incision length, total operative time and drilling bony time were shorter in the study group than in the control group(P < 0.05, respectively). All patients recovered well after the surgery without any severe complications.Conclusion: The use of a novel specialized retractor standardized the surgical processes of cochlear implantation. The retractor helped locate and control the size of the bony well during bone drilling. The tool reduced the technical difficulty and improved the efficacy of this minimally invasive operation.展开更多
基金supported by the Special Funds for National Excellent Doctoral Dissertation of Higher Education from the Ministry of Education (Project Number: 2007B67)the National Major Research Project (2014CB943003)
文摘Objective: The aim of this study was to improve muscle flaps and to evaluate surgical outcomes with the use of a novel specialized retractor, which is a surgical instrument used to locate and shape a bony seat for minimally invasive cochlear implantation.Methods: 50 patients aged 1 e75 years with sensorineural hearing loss who required cochlear implantation were recruited. A small incision(<3 cm) was made, and the novel specialized retractor was used in the study group during cochlear implantation. The incision length, surgical outcomes and operative time were recorded and analyzed.Results: The incision length, total operative time and drilling bony time were shorter in the study group than in the control group(P < 0.05, respectively). All patients recovered well after the surgery without any severe complications.Conclusion: The use of a novel specialized retractor standardized the surgical processes of cochlear implantation. The retractor helped locate and control the size of the bony well during bone drilling. The tool reduced the technical difficulty and improved the efficacy of this minimally invasive operation.