In recent years,a new generation of storage ring-based light sources,known as diffraction-limited storage rings(DLSRs),whose emittance approaches the diffraction limit for the range of X-ray wavelengths of interest to...In recent years,a new generation of storage ring-based light sources,known as diffraction-limited storage rings(DLSRs),whose emittance approaches the diffraction limit for the range of X-ray wavelengths of interest to the scientific community,has garnered significant attention worldwide.Researchers have begun to design and build DLSRs.Among various DLSR proposals,the hybrid multibend achromat(H-MBA)lattice enables sextupole strengths to be maintained at a reasonable level when minimizing the emittance;hence,it has been adopted in many DLSR designs.Based on the H-7BA lattice,the design of the Advanced Photon Source Upgrade Project(APS-U)can effectively reduce emittance by replacing six quadrupoles with anti-bends.Herein,we discuss the feasibility of designing an APS-U-type H-MBA lattice for the Southern Advanced Photon Source,a mid-energy DLSR light source with ultralow emittance that has been proposed to be built adjacent to the China Spallation Neutron Source.Both linear and nonlinear dynamics are optimized to obtain a detailed design of this type of lattice.The emittance is minimized,while a sufficiently large dynamic aperture(DA)and momentum acceptance(MA)are maintained.A design comprising 36 APS-U type H-7BAs,with an energy of 3 GeV and a circumference of 972 m,is achieved.The horizontal natural emittance is 20 pm·rad,with a horizontal DA of 5.8 mm,a vertical DA of 4.5 mm,and an MA of 4%,as well as a long longitudinal damping time of 120 ms.Subsequently,a few modifications are performed based on the APS-U-type lattice to reduce the maximum value of damping time from 120 to 44 ms while maintaining other performance parameters at the same level.展开更多
The 10-MeV Accelerator-Driven Subcritical(ADS)system Injector-I test stand at the Institute of High Energy Physics(IHEP)is a testing facility dedicated to demonstrating the feasibility of the spoke-based super-conduct...The 10-MeV Accelerator-Driven Subcritical(ADS)system Injector-I test stand at the Institute of High Energy Physics(IHEP)is a testing facility dedicated to demonstrating the feasibility of the spoke-based super-conducting(SC)linear accelerator(linac)for the ADS project in China.The injector adopted a four-vane copper structure radio frequency quadrupole(RFQ)with an output energy of 3.2 MeV and an SC section accommodating 14 β_(g)=0.12 single spoke cavities,14 SC solenoids,and 14 cold beam position monitors(BPMs).A 10-MeV pulsed beam with a beam current of 10 mA and a 2-mA continuous wave(CW)beam were successfully shooting through.The commissioning results confirmed the feasibility of using a 325-MHz spoke-type cavity for accelerating the proton beam in the low β and medium β sections.This paper describes the results achieved,the difficulties encountered,and the experiences obtained during commissioning.展开更多
Matrix-bound phosphine was determined in the Jiaozhou Bay coastal sediment, in prawn-pond bottom soil, in the eutrophic lake Wulongtan, in the sewage sludge and in paddy soil as well. Results showed that matrix-bound ...Matrix-bound phosphine was determined in the Jiaozhou Bay coastal sediment, in prawn-pond bottom soil, in the eutrophic lake Wulongtan, in the sewage sludge and in paddy soil as well. Results showed that matrix-bound phosphine levels in freshwater and coastal sediment, as well as in sewage sludge, are significantly higher than that in paddy soil. The correlation between matrix bound phosphine concentrations and organic phosphorus contents in sediment samples is discussed.展开更多
166.6-MHz quarter-waveβ=1 superconducting cavities have been adopted for the High Energy Photon Source,a 6-GeV diffraction-limited synchrotron light source currently under construction.A large helium jacket was requi...166.6-MHz quarter-waveβ=1 superconducting cavities have been adopted for the High Energy Photon Source,a 6-GeV diffraction-limited synchrotron light source currently under construction.A large helium jacket was required to accommodate the enlarged cavity beam pipe for the heavy damping of higher-order modes;the original electric-probe pickup thus becomes inevitably long with unfavorable mechanical properties.Relocated to an existing high-pressure-rinsing port,a magnetic-loop pickup was designed,characterized by low radio-frequency and cryogenic losses and being multipacting-free and insensitive to manufacturing and assembly tolerances.The consequent removal of the original pickup port from the cavity largely simplified the helium jacket fabrication and may also reduce cavity contamination.This paper presents a comprehensive design of a low-loss magnetic-coupling pickup for quarter-waveβ=1 superconducting cavities.The design can also be applied to other non-elliptical structures.展开更多
In contrast with the conventional injector consisting of dc gun, chopper, subharmonicbuncher and/or fundamental buncher, a microwave gun can cooperate with an alpha magnet as amore compact high brightness injector for...In contrast with the conventional injector consisting of dc gun, chopper, subharmonicbuncher and/or fundamental buncher, a microwave gun can cooperate with an alpha magnet as amore compact high brightness injector for the dedicated rf linear accelerators driving infrared freeelectron lasers (FELs). Such a concept has been put into practice in the MARK III FEL and willbe used in the Beijing Free Electron Laser (BFEL) as well. In this paper, the phase spread, energyspread, energy spread, emittance growth and intensity variation of a single electron microbunchin such an FEL accelerator system are investigated using SUPERFISH and PARMELA.展开更多
Ductal carcinoma in-situ (DCIS) has been visualized by 2D XDFI (X-ray dark-field imaging) and further by a 3D X-ray CT, and the data was acquired by the X-ray optics DEI (diffraction-enhanced imaging). A newly made al...Ductal carcinoma in-situ (DCIS) has been visualized by 2D XDFI (X-ray dark-field imaging) and further by a 3D X-ray CT, and the data was acquired by the X-ray optics DEI (diffraction-enhanced imaging). A newly made algorithm was used for CT. Data of 900 projections with interval of 0.2 degrees were used. Ductus lactiferi, microcalci-fication in a 3D form have been clearly visible. The spatial resolution available was approximately 30μm.展开更多
Permanent magnet rings are presented, which exploit the image effect in the surrounding circular iron shields. The theory is given for a general permanent ring when the magnetization orientation at each coordinate ang...Permanent magnet rings are presented, which exploit the image effect in the surrounding circular iron shields. The theory is given for a general permanent ring when the magnetization orientation at each coordinate angle ψ changes by =(n+1)ψ, where n is a positive or negative integer. For the uniformly magnetized case n=-1, the permanent ring produces no field in its bore, and the field is that of a dipole outside. When the ring is surrounded by a soft iron shield, its field becomes uniform in the bore, and zero outside the ring. The field can be varied continuously by moving the iron shield along the magnet axis. A small variable field device was constructed by using NdFeB permanent rings, which produced a field flux density of 0-0.5 T in the central region.展开更多
POLAR is a compact space-borne detector initially designed to measure the polarization of hard X-rays emitted from Gamma-Ray Bursts in the energy range 50–500 ke V.This instrument was launched successfully onboard th...POLAR is a compact space-borne detector initially designed to measure the polarization of hard X-rays emitted from Gamma-Ray Bursts in the energy range 50–500 ke V.This instrument was launched successfully onboard the Chinese space laboratory Tiangong-2(TG-2) on 2016 September 15.After being switched on a few days later,tens of gigabytes of raw detection data were produced in-orbit by POLAR and transferred to the ground every day.Before the launch date,a full pipeline and related software were designed and developed for the purpose of quickly pre-processing all the raw data from POLAR,which include both science data and engineering data,then to generate the high level scientific data products that are suitable for later science analysis.This pipeline has been successfully applied for use by the POLAR Science Data Center in the Institute of High Energy Physics(IHEP) after POLAR was launched and switched on.A detailed introduction to the pipeline and some of the core relevant algorithms are presented in this paper.展开更多
In-line phase-contrast computed tomography(IL-PC-CT) imaging is a new physical and biochemical imaging method.IL-PC-CT has advantages compared to absorption CT when imaging soft tissues. In practical applications, r...In-line phase-contrast computed tomography(IL-PC-CT) imaging is a new physical and biochemical imaging method.IL-PC-CT has advantages compared to absorption CT when imaging soft tissues. In practical applications, ring artifacts which will reduce the image quality are commonly encountered in IL-PC-CT, and numerous correction methods exist to either pre-process the sinogram or post-process the reconstructed image. In this study, we develop an IL-PC-CT reconstruction method based on anisotropic total variation(TV) minimization. Using this method, the ring artifacts are corrected during the reconstruction process. This method is compared with two methods: a sinogram preprocessing correction technique based on wavelet-FFT filter and a reconstruction method based on isotropic TV. The correction results show that the proposed method can reduce visible ring artifacts while preserving the liver section details for real liver section synchrotron data.展开更多
The dislocations in lithium tetraborate crystal have been investigated by means of synchrotron radiation white beam topography in BSRL(Beijing Synchrotron Radiation Laboratory).The Burgers'vectors of these disloca...The dislocations in lithium tetraborate crystal have been investigated by means of synchrotron radiation white beam topography in BSRL(Beijing Synchrotron Radiation Laboratory).The Burgers'vectors of these dislocations are determined by their vanishing conditions.Both screw and edge dislocations exist in the specimen.展开更多
基金This work was supported by the National Natural Science Foundation of China(No.11922512)the Youth Innovation Promotion Association of Chinese Academy of Sciences(No.Y201904)the Guangdong Basic and Applied Basic Research Foundation—Guangdong Dongguan Joint Foundation(No.2019B1515120069).
文摘In recent years,a new generation of storage ring-based light sources,known as diffraction-limited storage rings(DLSRs),whose emittance approaches the diffraction limit for the range of X-ray wavelengths of interest to the scientific community,has garnered significant attention worldwide.Researchers have begun to design and build DLSRs.Among various DLSR proposals,the hybrid multibend achromat(H-MBA)lattice enables sextupole strengths to be maintained at a reasonable level when minimizing the emittance;hence,it has been adopted in many DLSR designs.Based on the H-7BA lattice,the design of the Advanced Photon Source Upgrade Project(APS-U)can effectively reduce emittance by replacing six quadrupoles with anti-bends.Herein,we discuss the feasibility of designing an APS-U-type H-MBA lattice for the Southern Advanced Photon Source,a mid-energy DLSR light source with ultralow emittance that has been proposed to be built adjacent to the China Spallation Neutron Source.Both linear and nonlinear dynamics are optimized to obtain a detailed design of this type of lattice.The emittance is minimized,while a sufficiently large dynamic aperture(DA)and momentum acceptance(MA)are maintained.A design comprising 36 APS-U type H-7BAs,with an energy of 3 GeV and a circumference of 972 m,is achieved.The horizontal natural emittance is 20 pm·rad,with a horizontal DA of 5.8 mm,a vertical DA of 4.5 mm,and an MA of 4%,as well as a long longitudinal damping time of 120 ms.Subsequently,a few modifications are performed based on the APS-U-type lattice to reduce the maximum value of damping time from 120 to 44 ms while maintaining other performance parameters at the same level.
基金This work was supported by Strategic Priority Research Program of the Chinese Academy of Sciences(No.XDA03030201)the Key Laboratory of Particle Acceleration Physics and Technology Autonomous Foundation of CAS China(No.JSQ2017ZZ01).
文摘The 10-MeV Accelerator-Driven Subcritical(ADS)system Injector-I test stand at the Institute of High Energy Physics(IHEP)is a testing facility dedicated to demonstrating the feasibility of the spoke-based super-conducting(SC)linear accelerator(linac)for the ADS project in China.The injector adopted a four-vane copper structure radio frequency quadrupole(RFQ)with an output energy of 3.2 MeV and an SC section accommodating 14 β_(g)=0.12 single spoke cavities,14 SC solenoids,and 14 cold beam position monitors(BPMs).A 10-MeV pulsed beam with a beam current of 10 mA and a 2-mA continuous wave(CW)beam were successfully shooting through.The commissioning results confirmed the feasibility of using a 325-MHz spoke-type cavity for accelerating the proton beam in the low β and medium β sections.This paper describes the results achieved,the difficulties encountered,and the experiences obtained during commissioning.
文摘Matrix-bound phosphine was determined in the Jiaozhou Bay coastal sediment, in prawn-pond bottom soil, in the eutrophic lake Wulongtan, in the sewage sludge and in paddy soil as well. Results showed that matrix-bound phosphine levels in freshwater and coastal sediment, as well as in sewage sludge, are significantly higher than that in paddy soil. The correlation between matrix bound phosphine concentrations and organic phosphorus contents in sediment samples is discussed.
基金supported by High Energy Photon Source(HEPS)projecta major national science and technology infrastructure。
文摘166.6-MHz quarter-waveβ=1 superconducting cavities have been adopted for the High Energy Photon Source,a 6-GeV diffraction-limited synchrotron light source currently under construction.A large helium jacket was required to accommodate the enlarged cavity beam pipe for the heavy damping of higher-order modes;the original electric-probe pickup thus becomes inevitably long with unfavorable mechanical properties.Relocated to an existing high-pressure-rinsing port,a magnetic-loop pickup was designed,characterized by low radio-frequency and cryogenic losses and being multipacting-free and insensitive to manufacturing and assembly tolerances.The consequent removal of the original pickup port from the cavity largely simplified the helium jacket fabrication and may also reduce cavity contamination.This paper presents a comprehensive design of a low-loss magnetic-coupling pickup for quarter-waveβ=1 superconducting cavities.The design can also be applied to other non-elliptical structures.
文摘In contrast with the conventional injector consisting of dc gun, chopper, subharmonicbuncher and/or fundamental buncher, a microwave gun can cooperate with an alpha magnet as amore compact high brightness injector for the dedicated rf linear accelerators driving infrared freeelectron lasers (FELs). Such a concept has been put into practice in the MARK III FEL and willbe used in the Beijing Free Electron Laser (BFEL) as well. In this paper, the phase spread, energyspread, energy spread, emittance growth and intensity variation of a single electron microbunchin such an FEL accelerator system are investigated using SUPERFISH and PARMELA.
文摘Ductal carcinoma in-situ (DCIS) has been visualized by 2D XDFI (X-ray dark-field imaging) and further by a 3D X-ray CT, and the data was acquired by the X-ray optics DEI (diffraction-enhanced imaging). A newly made algorithm was used for CT. Data of 900 projections with interval of 0.2 degrees were used. Ductus lactiferi, microcalci-fication in a 3D form have been clearly visible. The spatial resolution available was approximately 30μm.
文摘Permanent magnet rings are presented, which exploit the image effect in the surrounding circular iron shields. The theory is given for a general permanent ring when the magnetization orientation at each coordinate angle ψ changes by =(n+1)ψ, where n is a positive or negative integer. For the uniformly magnetized case n=-1, the permanent ring produces no field in its bore, and the field is that of a dipole outside. When the ring is surrounded by a soft iron shield, its field becomes uniform in the bore, and zero outside the ring. The field can be varied continuously by moving the iron shield along the magnet axis. A small variable field device was constructed by using NdFeB permanent rings, which produced a field flux density of 0-0.5 T in the central region.
基金financial support from the Joint Research Fund in Astronomy under a cooperative agreement between the National Natural Science Foundation of China and the Chinese Academy of Sciences (Grant No. U1631242)the National Natural Science Foundation of China (Grant Nos. 11503028 and 11403028)+1 种基金the Strategic Priority Research Program of the Chinese Academy of Sciences (XDB23040400)the National Basic Research Program (973 Program) of China (2014CB845800)
文摘POLAR is a compact space-borne detector initially designed to measure the polarization of hard X-rays emitted from Gamma-Ray Bursts in the energy range 50–500 ke V.This instrument was launched successfully onboard the Chinese space laboratory Tiangong-2(TG-2) on 2016 September 15.After being switched on a few days later,tens of gigabytes of raw detection data were produced in-orbit by POLAR and transferred to the ground every day.Before the launch date,a full pipeline and related software were designed and developed for the purpose of quickly pre-processing all the raw data from POLAR,which include both science data and engineering data,then to generate the high level scientific data products that are suitable for later science analysis.This pipeline has been successfully applied for use by the POLAR Science Data Center in the Institute of High Energy Physics(IHEP) after POLAR was launched and switched on.A detailed introduction to the pipeline and some of the core relevant algorithms are presented in this paper.
基金supported by the National Natural Science Foundation of China(Grant Nos.61671004,61271012,81371549,81671683,and 11501415)the Natural Science Foundation of Tianjin City,China(Grant No.16JCYBJC28600)+4 种基金the WBE Liver Fibrosis Foundation of China(Grant No.CFHPC20131033)the Instrument Developing Project of the Chinese Academy of Sciences(Grant No.YZ201410)the Foundation of Tianjin University of Technology and Education(Grant Nos.KJ11-22 and J10011060321)SRF for ROCS,SEMthe IHEP-CAS Scientific Research Foundation(Grant No.2013IHEPYJRC801)
文摘In-line phase-contrast computed tomography(IL-PC-CT) imaging is a new physical and biochemical imaging method.IL-PC-CT has advantages compared to absorption CT when imaging soft tissues. In practical applications, ring artifacts which will reduce the image quality are commonly encountered in IL-PC-CT, and numerous correction methods exist to either pre-process the sinogram or post-process the reconstructed image. In this study, we develop an IL-PC-CT reconstruction method based on anisotropic total variation(TV) minimization. Using this method, the ring artifacts are corrected during the reconstruction process. This method is compared with two methods: a sinogram preprocessing correction technique based on wavelet-FFT filter and a reconstruction method based on isotropic TV. The correction results show that the proposed method can reduce visible ring artifacts while preserving the liver section details for real liver section synchrotron data.
文摘The dislocations in lithium tetraborate crystal have been investigated by means of synchrotron radiation white beam topography in BSRL(Beijing Synchrotron Radiation Laboratory).The Burgers'vectors of these dislocations are determined by their vanishing conditions.Both screw and edge dislocations exist in the specimen.