Recently,renewable power generation and electric vehicles(EVs)have been attracting more and more attention in smart grid.This paper presents a grid-connected solar-wind hybrid system to supply the electrical load dema...Recently,renewable power generation and electric vehicles(EVs)have been attracting more and more attention in smart grid.This paper presents a grid-connected solar-wind hybrid system to supply the electrical load demand of a small shopping complex located in a university campus in India.Further,an EV charging station is incorporated in the system.Economic analysis is performed for the proposed setup to satisfy the charging demand of EVs as well as the electrical load demand of the shopping complex.The proposed system is designed by considering the cost of the purchased energy,which is sold to the utility grid,while the power exchange is ensured between the utility grid and other components of the system.The sizing of the component is performed to obtain the least levelized cost of electricity(LCOE)while minimizing the loss of power supply probability(LPSP)by using recent optimization techniques.The results demonstrate that the LCOE and LPSP for the proposed system are measured at 0.038$/k Wh and0.19%with a renewable fraction of 0.87,respectively.It is determined that a cost-effective and reliable system can be designed by the proper management of renewable power generation and load demands.The proposed system may be helpful in reducing the reliance on the over-burdened grid,particularly in developing countries.展开更多
文摘Recently,renewable power generation and electric vehicles(EVs)have been attracting more and more attention in smart grid.This paper presents a grid-connected solar-wind hybrid system to supply the electrical load demand of a small shopping complex located in a university campus in India.Further,an EV charging station is incorporated in the system.Economic analysis is performed for the proposed setup to satisfy the charging demand of EVs as well as the electrical load demand of the shopping complex.The proposed system is designed by considering the cost of the purchased energy,which is sold to the utility grid,while the power exchange is ensured between the utility grid and other components of the system.The sizing of the component is performed to obtain the least levelized cost of electricity(LCOE)while minimizing the loss of power supply probability(LPSP)by using recent optimization techniques.The results demonstrate that the LCOE and LPSP for the proposed system are measured at 0.038$/k Wh and0.19%with a renewable fraction of 0.87,respectively.It is determined that a cost-effective and reliable system can be designed by the proper management of renewable power generation and load demands.The proposed system may be helpful in reducing the reliance on the over-burdened grid,particularly in developing countries.