Auxiliary frequency control of a wind turbine generator(WTG) has been widely used to enhance the frequencysecurity of power systems with high penetration of renewableenergy. Previous studies recommend two types of con...Auxiliary frequency control of a wind turbine generator(WTG) has been widely used to enhance the frequencysecurity of power systems with high penetration of renewableenergy. Previous studies recommend two types of control schemes,including frequency droop control and emulated inertia control,which simulate the response characteristics of the synchronousgenerator (SG). This paper plans to further explore the optimalauxiliary frequency control of the wind turbine based on previousresearch. First, it is determined that the virtual inertia control haslittle effect on the maximum rate of change of frequency (MaxROCOF)if the time delay of the control link of WTG is taken intoconsideration. Secondly, if a WTG operates in maximum powerpoint tracking (MPPT) mode and uses the rotor deceleration forfrequency modulation, its optimal auxiliary frequency control willcontain only droop control. Furthermore, if the droop control isproperly delayed, better system frequency response (SFR) willbe obtained. The reason is that coordination between the WTGand SG is important for SFR when the frequency modulationcapability of the WTG is limited. The frequency modulationcapability of the WTG is required to be released more properly.Therefore, when designing optimal auxiliary frequency controlfor the WTG, a better control scheme is worth further study.展开更多
基金the National Natural Science Foundation of China(51922061)the Science and Technology Project of State Grid Corporation of China(SGZJ0000KXJS1900418).
文摘Auxiliary frequency control of a wind turbine generator(WTG) has been widely used to enhance the frequencysecurity of power systems with high penetration of renewableenergy. Previous studies recommend two types of control schemes,including frequency droop control and emulated inertia control,which simulate the response characteristics of the synchronousgenerator (SG). This paper plans to further explore the optimalauxiliary frequency control of the wind turbine based on previousresearch. First, it is determined that the virtual inertia control haslittle effect on the maximum rate of change of frequency (MaxROCOF)if the time delay of the control link of WTG is taken intoconsideration. Secondly, if a WTG operates in maximum powerpoint tracking (MPPT) mode and uses the rotor deceleration forfrequency modulation, its optimal auxiliary frequency control willcontain only droop control. Furthermore, if the droop control isproperly delayed, better system frequency response (SFR) willbe obtained. The reason is that coordination between the WTGand SG is important for SFR when the frequency modulationcapability of the WTG is limited. The frequency modulationcapability of the WTG is required to be released more properly.Therefore, when designing optimal auxiliary frequency controlfor the WTG, a better control scheme is worth further study.